arrow
返回

Data-driven dose calculation algorithm based on deep U-Net

delete2020-12-11
delete28
delete
OA
AI
J
Jiawei Fan
邢
邢磊 (Lei Xing) *
P
Peng Dong
J
Jiazhou Wang
W
Weigang Hu
Y
Yong Yang
DOI:10.1088/1361-6560/abca05delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Accurate and efficient dose calculation is an important prerequisite to ensure the success of radiation therapy. However, all the dose calculation algorithms commonly used in current clinical practice have to compromise between calculation accuracy and efficiency, which may result in unsatisfactory dose accuracy or highly intensive computation time in many clinical situations. The purpose of this work is to develop a novel dose calculation algorithm based on the deep learning method for radiation therapy. In this study we performed a feasibility investigation on implementing a fast and accurate dose calculation based on a deep learning technique. A two-dimensional (2D) fluence map was first converted into a three-dimensional (3D) volume using ray traversal algorithm. 3D U-Net like deep residual network was then established to learn a mapping between this converted 3D volume, CT and 3D dose distribution. Therefore an indirect relationship was built between a fluence map and its corresponding 3D dose distribution without using significantly complex neural networks. Two hundred patients, including nasopharyngeal, lung, rectum and breast cancer cases, were collected and applied to train the proposed network. Additional 47 patients were randomly selected to evaluate the accuracy of the proposed method through comparing dose distributions, dose volume histograms and clinical indices with the results from a treatment planning system (TPS), which was used as the ground truth in this study. The proposed deep learning based dose calculation algorithm achieved good predictive performance. For 47 tested patients, the average per-voxel bias of the deep learning calculated value and standard deviation (normalized to the prescription), relative to the TPS calculation, is 0.17%+/- 2.28%. The average deep learning calculated values and standard deviations for relevant clinical indices were compared with the TPS calculated results and the t-test p-values demonstrated the consistency between them. In this study we developed a new deep learning based dose calculation method. This approach was evaluated by the clinical cases with different sites. Our results demonstrated its feasibility and reliability and indicated its great potential to improve the efficiency and accuracy of radiation dose calculation for different treatment modalities.
Keyword:
deep learning
data driven
dose calculation

期刊

Physics in Medicine and Biology 封面图
Physics in Medicine and Biology
IF:
3.4
论文数:
1.4W
被引数:
3.1W

机构

F
fudan university
学者数:
11.8W
论文数: 7.7W
被引数: 121
S
Stanford University
学者数:
9.6W
论文数: 8.2W
被引数: 17.0W
引用论文

引用论文

ScatterNet: A convolutional neural network for cone-beam CT intensity correction
err2018-10-08
err128
PREAI
errHansen, David C.; Landry, Guillaume; Kamp, Florian; Li, Minglun; Belka, Claus; Parodi, Katia; Kurz, Christopher
err分享
err收藏
Comparing Unet training with three different datasets to correct CBCT images for prostate radiotherapy dose calculations
err2019-01-24
err77
PREAI
errLandry, Guillaume; Hansen, David; Kamp, Florian; Li, Minglun; Hoyle, Ben; Weller, Jochen; Parodi, Katia; Belka, Claus; Kurz, Christopher
err分享
err收藏
err分享
err收藏
The Topp–Leone odd log-logistic family of distributions
err2017-07-17
err0
PREAI
errE. Brito; G. M. Cordeiro; H. M. Yousof; M. Alizadeh; G. O. Silva
err分享
err收藏
学者 查看更多内容