返回
Dead-Time Compensation Method Based on Current Ripple Estimation
DOI:10.1109/TPEL.2014.2352716.png)
摘要
En 中文
This paper discusses the voltage error caused by the dead time in voltage-source PWM converters. The theoretical analysis in this paper derives the nonlinear voltage error paying attention to the parasitic output capacitance in each switching device. The analytical result reveals that the turn-off current or the switching current ripple strongly affects the voltage error. In addition, it is clarified that the conventional compensation methods based on linear and three-level approximation are suitable under small and large current ripple conditions, respectively. A simple calculation method of current ripples in three-phase PWM converters is also developed to estimate the turn-off currents. Turn-off transition compensation method which is a new compensation method based on the analysis is developed and compared with three different conventional-methods in experiments using a 200-V, 5-kW three-phase grid-connection converter. The proposed method exhibits a good compensation performance having a lower voltage THD than the conventional methods in all over the operating range.
Keyword:
Current ripples
dead time
grid connection converters
output stray capacitance
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
6.5
论文数:
1.7W
被引数:
8.3W
机构
引用论文
Improved dead-time compensation for sinusoidal PWM inverters operating at high switching frequencies改进的高开关频率正弦PWM逆变器死区补偿
Adaptive Dead-Time Compensation for Grid-Connected PWM Inverters of Single-Stage PV Systems单级光伏并网PWM逆变器的自适应死区补偿
On the compensation of dead time and zero-current crossing for a PWM-inverter-controlled AC servo drive关于PWM逆变器控制的交流伺服驱动器的死区时间和零电流交叉的补偿
Repetitive-control-based self-commissioning procedure for inverter nonidealities compensation用于逆变器非理想补偿的基于重复控制的自调试程序