返回
Dead-time issues in predictive current control
DOI:10.1109/TIA.2004.827772.png)
摘要
En 中文
Current control in inverter-driven machine systems is the inner most component of the hierarchy of control loops. If the control of current in the machine is not fast and accurate then it is difficult, if not impossible, to build a high-performance drive system. Unfortunately, the implementation of current control in power electronic systems is not ideal. Practical effects can have a significant influence on its performance. This paper examines one of these effects, dead time, and considers the influence it has on the performance of predictive current controllers (PCCs). The paper presents analysis that shows that a PCC implicitly compensates for voltage loss due to dead time. Also, a modified PCC is introduced that reduces the zero-current-clamp problem caused by dead time. Simulation and experimental results are presented to verify the analysis and confirm the performance of the new algorithm.
Keyword:
current clamp
inverter dead time
predictive current controller (PCC)
pulsewidth modulation (PWM)
期刊
IF:
4.5
论文数:
1.1W
被引数:
3.5W
机构
暂无机构信息
引用论文
Spatiotemporal Characteristics of Urban Surface Temperature and Its Relationship with Landscape Metrics and Vegetation Cover in Rapid Urbanization Region
Complexity
IF0