Deconvolution-based partial volume correction of PET images with parallel level set regularization

delete2021-07-09
delete6
delete
OA
AI
Y
Yansong Zhu *
M
Murat Bilgel
Y
Yuanyuan Gao
O
Olivier Rousset
S
Susan M. Resnick
D
Dean F. Wong
A
Arman Rahmim *
DOI:10.1088/1361-6560/ac0d8fdelete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
The partial volume effect (PVE), caused by the limited spatial resolution of positron emission tomography (PET), degrades images both qualitatively and quantitatively. Anatomical information provided by magnetic resonance (MR) images has the potential to play an important role in partial volume correction (PVC) methods. Post-reconstruction MR-guided PVC methods typically use segmented MR tissue maps, and further, assume that PET activity distribution is uniform in each region, imposing considerable constraints through anatomical guidance. In this work, we present a post-reconstruction PVC method based on deconvolution with parallel level set (PLS) regularization. We frame the problem as an iterative deconvolution task with PLS regularization that incorporates anatomical information without requiring MR segmentation or assuming uniformity of PET distributions within regions. An efficient algorithm for non-smooth optimization of the objective function (invoking split Bregman framework) is developed so that the proposed method can be feasibly applied to 3D images and produces sharper images compared to PLS method with smooth optimization. The proposed method was evaluated together with several other PVC methods using both realistic simulation experiments based on the BrainWeb phantom as well as in vivo human data. Our proposed method showed enhanced quantitative performance when realistic MR guidance was provided. Further, the proposed method is able to reduce image noise while preserving structure details on in vivo human data, and shows the potential to better differentiate amyloid positive and amyloid negative scans. Overall, our results demonstrate promise to provide superior performance in clinical imaging scenarios.
Keyword:
anatomical prior
deconvolution
positron emission tomography (PET)
partial volume correction (PVC)

期刊

Physics in Medicine and Biology 封面图
Physics in Medicine and Biology
IF:
3.4
论文数:
1.4W
被引数:
3.1W

机构

N
national institutes of health (nih) - usa
学者数:
10.3W
论文数: 8.2W
被引数: 111
N
nih national institute on aging (nia)
学者数:
4.9K
论文数: 3.6K
被引数: 2
J
Johns Hopkins University
学者数:
10.2W
论文数: 8.8W
被引数: 13.0W
S
southern medical university - china
学者数:
4.6W
论文数: 2.5W
被引数: 50
学者 查看更多机构
引用论文

引用论文

Polypropylene/graphene nanosheet nanocomposites by in situ polymerization: Synthesis, characterization and fundamental properties
err2013-07-01
err0
PREAI
errMarcéo A. Milani; Darío González; Raúl Quijada; Nara R.S. Basso; Maria L. Cerrada; Denise S. Azambuja; Griselda B. Galland
err分享
err收藏
err分享
err收藏
err分享
err收藏
Coordination Properties of the Oxime Analogue of Glycine to Cu(II)
err2005-06-04
err0
PREAI
errI. Georgieva; N. Trendafilova; L. Rodríguez-Santiago; M. Sodupe
err分享
err收藏
Attenuation Correction Methods Suitable for Brain Imaging with a PET/MRI Scanner: A Comparison of Tissue Atlas and Template Attenuation Map Approaches
err2011-07-01
err84
errOAAI
errMalone, Ian B.; Ansorge, Richard E.; Williams, Guy B.; Nestor, Peter J.; Carpenter, T. Adrian; Fryer, Tim D.
err分享
err收藏
PET/MR Imaging: Technical Aspects and Potential Clinical Applications
errRADIOLOGY
IF15.2
err2013-04-01
err191
PREAI
errTorigian, Drew A.; Zaidi, Habib; Kwee, Thomas C.; Saboury, Babak; Udupa, Jayaram K.; Cho, Zang-Hee; Alavi, Abass
err分享
err收藏
学者 查看更多内容