Developing a Microbubble-Based Contrast Agent for Synchrotron Multiple-Image Radiography

delete2022-02-08
delete0
PRE
AI
N
Ngoc Ton
U
Una Goncin
A
Arash Panahifar
M
M. Adam Webb
L
L. D. Chapman
S
Sheldon Wiebe
S
Steven Machtaler *
DOI:10.1007/s11307-022-01705-5delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Purpose Multiple-image radiography (MIR) is an analyzer-based synchrotron X-ray imaging approach capable of dissociating absorption, refraction, and scattering components of X-ray interaction with the material. It generates additional image contrast mechanisms (besides absorption), especially in the case of soft tissues, while minimizing absorbed radiation dose. Our goal is to develop a contrast agent for MIR using ultrasound microbubbles by carrying out a systematic assessment of size, shell material, and concentration. Procedures Microbubbles were synthesized with two different shell materials: phospholipid and polyvinyl-alcohol. Polydisperse perfluorobutane-filled lipid microbubbles were divided into five size groups using centrifugation. Two distributions of air-filled polymer microbubbles were generated: 2-3 mu m and 3-4 mu m. A subset of polymer microbubbles 3-4 mu m had iron oxide nanoparticles incorporated into their shell or coated on their surface. Microbubbles were immobilized in agar with different concentrations: 5 x 10(7), 5 x 10(6), and 5 x 10(5) MBs/ml. MIR was conducted on the BioMedical Imaging and Therapy beamline at the Canadian Light Source. Three images were generated: Gaussian amplitude, refraction, and ultra-small-angle X-ray scattering (USAXS). The contrast signal was quantified by measuring mean pixel values and comparing them with agar. Results No difference was detected in absorption or refraction images of all tested microbubbles. Using USAXS, a significant signal increase was observed with lipid microbubbles 6-10 mu m at the highest concentration (p = 0.02), but no signal was observed at lower concentrations. Conclusions These data indicate that lipid microbubbles 6-10 mu m are candidates as contrast agents for MIR, specifically for USAXS. A minimum concentration of 5 x 10(7) microbubbles (lipid-shell 6-10 mu m) per milliliter was needed to generate a detectable signal.
Keyword:
Contrast agents
Multiple-image radiography
Microbubbles
Synchrotron
Ultra-small-angle X-ray scattering

期刊

Molecular Imaging and Biology 封面图
Molecular Imaging and Biology
IF:
2.5
论文数:
2.1K
被引数:
3.0K

机构

U
University of Saskatchewan
学者数:
1.5W
论文数: 1.4W
被引数: 1.7W
引用论文

引用论文

err分享
err收藏
A Gaussian extension for Diffraction Enhanced Imaging
err2018-01-10
err17
errOAAI
errArfelli, Fulvia; Astolfo, Alberto; Rigon, Luigi; Menk, Ralf Hendrik
err分享
err收藏
Linear-nonlinear-time-warp-poisson models of neural activity
err2018-10-08
err0
errOAAI
errPatrick N. Lawlor; Matthew G. Perich; Lee E. Miller; Konrad P. Kording
err分享
err收藏
err分享
err收藏
A generalized quantitative interpretation of dark-field contrast for highly concentrated microsphere suspensions
err2016-10-13
err29
errOAAI
errGkoumas, Spyridon; Villanueva-Perez, Pablo; Wang, Zhentian; Romano, Lucia; Abis, Matteo; Stampanoni, Marco
err分享
err收藏
Talbot phase-contrast x-ray imaging for the small joints of the hand
err2011-08-12
err107
errOAAI
errStutman, Dan; Beck, Thomas J.; Carrino, John A.; Bingham, Clifton O.
err分享
err收藏
err分享
err收藏
学者 查看更多内容