Developing a spectroradiometer data uncertainty methodology

delete2017-06-01
delete4
delete
OA
AI
J
Josh Peterson *
F
Frank Vignola
A
Aron Habte
M
Manajit Sengupta
DOI:10.1016/j.solener.2017.03.075delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
The proper calibration and measurement uncertainty of spectral data obtained from spectroradiometers is essential in accurately quantifying the output of photovoltaic(PV) devices. PV cells and modules are initially characterized using solar simulators but field performance is evaluated using natural sunlight. Spectroradiometers are used to measure the spectrum of both these light sources in an effort to understand the spectral dependence of various PV output capabilities. These chains of characterization and measurement are traceable to National Metrology Institutes such as National Institute of Standards and Technology, and therefore there is a need for a comprehensive uncertainty methodology to determine the accuracy of spectroradiometer data. In this paper, the uncertainties associated with the responsivity of a spectroradiometer are examined using the Guide to the Expression of Uncertainty in Measurement (GUM) protocols. This is first done for a generic spectroradiometer, and then, to illustrate the methodology, the calibration of a LI-COR 1800 spectroradiometer is performed. The reader should be aware that the implementation of this methodology will be specific to the spectroradiometer being analyzed and the experimental setup that is used. Depending of the characteristics of the spectroradiometer being evaluated additional sources of uncertainty may need to be included, but the general GUM methodology is the same. Several sources of uncertainty are associated with the spectroradiometer responsivity. Major sources of uncertainty associated with the LI-COR spectroradiometer are noise in the signal at wavelengths less than 400 nm. At wavelengths more than 400 nm, the responsivity can vary drastically, and it is dependent on the wavelength of light, the temperature dependence, the angle of incidence, and the azimuthal orientation of the sensor to the light source. The expanded uncertainties in the responsivity of the LI-COR spectroradiometer in the wavelength range of 400-1050 nm can range from 4% to 14% at the 95% confidence level. (C) 2017 The Authors. Published by Elsevier Ltd.
Keyword:
Spectroradiometer
Uncertainty
Cosine response
LI-COR 1800
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Solar Energy 封面图
Solar Energy
IF:
6.6
论文数:
1.4W
被引数:
6.2W

机构

U
university of oregon
学者数:
6.5K
论文数: 6.1K
被引数: 6
U
united states department of energy (doe)
学者数:
11.3W
论文数: 9.6W
被引数: 246
引用论文

引用论文

Surface crack growth simulation under mixed mode cyclic loading condition
err2011-01-01
err0
errOAAI
errMasanori Kikuchi; Yoshitaka Wada; Kazuhiro Suga
err分享
err收藏
Economic evaluation of photodynamic therapy with verteporfin
err2003-06-01
err0
PREAI
errMichael J Lees; Graily J.R. Aldridge; Peter J. Davey; Mende Gorgievski
err分享
err收藏
Introductory overview of research instruments for recording the electrical activity of neurons in the human brain
err1998-12-01
err0
PREAI
errP. C. Garell; M. A. Granner; M. D. Noh; M. A. Howard; I. O. Volkov; G. T. Gillies
err分享
err收藏
err分享
err收藏
没有更多内容