1
Return

Development of an expert-annotated chest X-ray dataset to support AI validation in tuberculosis diagnosis

delete2026-07-10
delete0
delete
OA
AI
W
Wiwatana Tanomkiat *
S
Shiva Raj Timsina
T
Thammasin Ingviya
S
Sitthichok Chaichulee
P
Patinya Yutchawit
C
Chiawchan Thuncharoenkanka
W
Wuttikrai Pannuan
C
Chureerat Chantharat
U
Urasri Kerdmeesup
N
Nantaka Kiranantawat
S
Sitang Nirattisaikul
S
Sutarat Tungsagunwattana
K
Krisna Dissaneevate
W
Warawut Sukkasem
C
Chanavee Toh
S
Suthinee Teerajaruwat
DOI:10.1186/s13244-026-02334-0delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
To assess inter-rater agreement and diagnostic performance of six United States National Institute for Occupational Safety and Health-certified B readers (physicians certified in standardized chest X-ray (CXR) classification for pneumoconiosis) in diagnosing tuberculosis (TB) on CXR, with the goal of developing a reliable dataset to support external validation of artificial intelligence (AI) models for TB detection. 1097 CXRs from five institutions were analyzed by six B readers. Patients aged ≥ 15 years were included, excluding those with HIV or opportunistic infections. CXRs were classified as unremarkable or abnormal. Abnormalities were categorized using a modified International Labor Organization classification and classified as consistent or inconsistent with TB. Microbiological references included sputum smears, cultures, or molecular tests. Descriptive statistics summarized the CXR and microbiological findings. Inter-rater agreement was assessed with Fleiss’ kappa. Diagnostic performance was evaluated by comparing CXR findings to microbiological references. Of the 3117 readings, 69% of CXRs were abnormal, and 31% were unremarkable. Microbiological results confirmed that 87% of abnormal CXRs were TB cases, while 83% of unremarkable CXRs were non-TB. Inter-rater agreements were κ = 0.83 for all findings, κ = 0.67 for findings consistent with TB, and κ = 0.76 for active TB findings. For findings consistent with TB, the sensitivity, specificity, and accuracy ranged from 77.2% to 91.1%, 87.4% to 98.6%, and 84.1% to 90.1%, respectively. B readers exhibited strong agreement and high accuracy in diagnosing TB on CXR, providing a robust dataset that could be used for external validation of AI models in TB diagnosis. With substantial inter-rater agreement and strong diagnostic performance, B readers’ interpretations of CXRs provide a reliable dataset to support external validation of AI models for TB diagnosis.
Keywords:
Tuberculosis
Chest X-ray
B readers
Inter-rater agreement
Artificial intelligence
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

Insights into Imaging cover
Insights into Imaging
IF:
4.5
Papers:
1.8K
Citations:
7.5K

Organization

C
College of Medicine
Scholars:
3.7K
Papers: 1.5K
Citations: 3
D
department of radio-diagnosis and imaging
Scholars:
2
Papers: 1
Citations: 0
R
radiology department
Scholars:
396
Papers: 223
Citations: 1
C
Central Chest Institute of Thailand
Scholars:
4
Papers: 3
Citations: 0
R
ramathibodhi hospital
Scholars:
2
Papers: 1
Citations: 0
D
Department of Disease Control
Scholars:
44
Papers: 22
Citations: 119
F
faculty of medicine
Scholars:
6.2K
Papers: 2.1K
Citations: 0
Cited Papers

Cited Papers

Citing Papers

Citing Papers