arrow
返回

Diffusion tensor fiber tracking on graphics processing units

delete2008-10-01
delete12
PRE
AI
A
Adiel Mittmann *
E
Eros Comunello
A
Aldo von Wangenheim
DOI:10.1016/j.compmedimag.2008.05.006delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Diffusion tensor magnetic resonance imaging has been successfully applied to the process of fiber tracking, which determines the location of fiber bundles within the human brain. This process, however, can be quite lengthy when run on a regular workstation. We present a means of executing this process by making use of the graphics processing units of computers' video cards, which provide a low-cost parallel execution environment that algorithms like fiber tracking can benefit from. With this method we have achieved performance gains varying from 14 to 40 times on common computers. Because of accuracy issues inherent to current graphics processing units, we define a variation index in order to assess how close the results obtained with our method are to those generated by programs running on the central processing units of computers. This index shows that results produced by our method are acceptable when compared to those of traditional programs. (C) 2008 Elsevier Ltd. All rights reserved.
Keyword:
Diffusion tensor imaging
Fiber tracking
Graphics processing units
Fiber tracking results comparison
Performance optimization
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Computerized Medical Imaging and Graphics 封面图
Computerized Medical Imaging and Graphics
IF:
4.9
论文数:
2.4K
被引数:
5.0K

机构

U
universidade federal de santa catarina (ufsc)
学者数:
1.5W
论文数: 1.1W
被引数: 9
引用论文

引用论文

Controlled modification of erbium lifetime by near-field coupling to metallic films
err2009-01-30
err0
errOAAI
errNanfang Yu; Alexey Belyanin; Jiming Bao; Federico Capasso
err分享
err收藏
Motion compensation in digital subtraction angiography using graphics hardware
err2006-07-01
err15
PREAI
errDeuerling-Zheng, Yu; Lell, Michael; Galant, Adam; Hornegger, Joachim
err分享
err收藏
Processing and visualization for diffusion tensor MRI弥散张量MRI的处理与可视化
err2002-06-01
err722
PREAI
errWestin, CF; Maier, SE; Mamata, H; Nabavi, A; Jolesz, FA; Kikinis, R
err分享
err收藏
Distribution Quality of Agrochemicals for the Revamping of a Sprayer System Based on Lidar Technology and Grapevine Disease Management
err2023-02-09
err0
errOAAI
errAlessio Ilari; Simone Piancatelli; Luana Centorame; Marwa Moumni; Gianfranco Romanazzi; Ester Foppa Pedretti
err分享
err收藏
Tracking neuronal fiber pathways in the living human brain
err1999-08-31
err1.6K
errOAAI
errConturo, TE; Lori, NF; Cull, TS; Akbudak, E; Snyder, AZ; Shimony, JS; McKinstry, RC; Burton, H; Raichle, ME
err分享
err收藏
19. Paleomagnetic constraints on the Atapuerca karst development (N Spain)19。古地磁对Atapuerca岩溶发育的限制 (西班牙)
err2024-08-05
err0
PREAI
errJ.M. Parés; A.I. Ortega; A. Benito-Calvo; A. Aranburu; J.L. Arsuaga; J.M. Bermúdez de Castro; E. Carbonell
err分享
err收藏
DT-MRI denoising and neuronal fiber tracking
err2004-06-01
err81
PREAI
errMcGraw, T; Vemuri, BC; Chen, Y; Rao, M; Mareci, T
err分享
err收藏
学者 查看更多内容