arrow
返回

Digital image-based titrations

delete2006-06-01
delete112
PRE
AI
E
Edvaldo da Nóbrega Gaião
W
Wellington da Silva Lyra
L
Luciano F. Almeida
M
Mário César Ugulino de Araújo *
DOI:10.1016/j.aca.2006.04.048delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
The exploitation of digital images obtained from a CCD camera (WebCam) as a novel instrumental detection technique for titration is proposed for the first time. Named of digital image-based (DIB) titration, it also requires, as a traditional titration (for example, spectrophotometric, potentiometric, conductimetric), a discontinuity in titration curves where there is an end point, which is associated to the chemical equivalence condition. The monitored signal in the DIB titration is a RGB-based value that is calculated, for each digital image, by using a proposed procedure based on the red, green, and blue colour system. The DIB titration was applied to determine HCI and H3PO4 in aqueous solutions and total alkalinity in mineral and tap waters. Its results were compared to the spectrophotometric (SPEC) titration and, by applying the paired t-test, no statistic difference between the results of both methods was verified at the 95% confidence level. Identical standard deviations were obtained by both titrations in the determinations of HCI and H3PO4, with a slightly better precision for DIB titration in the determinations of total alkalinity. The DIB titration shows to be an efficient and promising tool for quantitative chemical analysis and, as it employs an inexpensive device (WebCam) as analytical detector, it offers an economically viable alternative to titrations that need instrumental detection. (c) 2006 Elsevier B.V. All rights reserved.
Keyword:
digital images
RGB colour system
DIB titration
alkalinity
waters analysis

期刊

Analytica Chimica Acta 封面图
Analytica Chimica Acta
IF:
6
论文数:
3.3W
被引数:
6.1W

机构

暂无机构信息
引用论文

引用论文

Automated evaluation of food colour by means of multivariate image analysis coupled to a wavelet-based classification algorithm
err2004-07-01
err100
PREAI
errAntonelli, A; Cocchi, M; Fava, P; Foca, G; Franchini, CG; Manzini, D; Ulrici, A
err分享
err收藏
err分享
err收藏
err分享
err收藏
Screening analysis of river seston downstream of an effluent discharge point using near-infrared reflectance spectrometry and wavelet-based spectral region selection
err2005-08-01
err11
PREAI
errDe Medeiros, VM; Araújo, MCU; Galvao, RKH; Da Silva, EC; Saldanha, TCB; Toscano, IAS; De Oliveira, MDSR; Freitas, SKB; Neto, MM
err分享
err收藏
Robust modeling for multivariate calibration transfer by the successive projections algorithm
err2005-03-01
err60
PREAI
errHonorato, FA; Galvao, RKH; Pimentel, MF; Neto, BD; Araújo, MCU; de Carvalho, FR
err分享
err收藏
Intracellular Ph
err1969-01-01
err0
PREAI
errJ.S. Robson; J.M. Bone; Anne T. Lambie
err分享
err收藏
Hardness screening of water using a flow-batch photometric system使用流式光度系统对水进行硬度筛选
err2004-08-01
err49
PREAI
errLima, RAC; Santos, SRB; Costa, RS; Marcone, GPS; Honorato, RS; Nascimento, VB; Araujo, MCU
err分享
err收藏
学者 查看更多内容