Direct dynamic tomographic reconstruction without explicit blood input function

delete2023-02-01
delete0
delete
OA
AI
L
László Szirmay‐Kalos *
M
Milán Magdics
D
Dóra Varnyú
DOI:10.1016/j.bspc.2022.104313delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
With dynamic positron emission tomography (PET), we study the metabolic processes by monitoring the uptake of a radioactive tracer. The goal is to reconstruct the time-activity curves (TACs) of the voxels, from which the relevant kinetic parameters can be obtained. These curves are assumed to have the algebraic form of a pre-determined kinetic model. Plausible algebraic forms have a limited number of free parameters and thus can be used even for low-statistic measurements. The kinetic model typically involves the amount of radiotracer in the blood, which should be determined either by direct measurement or by extracting it from the PET data using image-derived or model-based methods. However, the direct measurement of the blood concentration is complicated, and the results of the image-derived and the model-based methods are also not reliable because of the partial volume effect and the unknown fraction of blood in the voxels. Moreover, in direct dynamic tomography, the kinetic model is fit from the very beginning of the reconstruction, thus the blood input function is needed even before the image-derived or model-based approaches can provide it. In this paper, we propose a method that is based on compartmental modeling and the Feng blood input function model defined by a fourth-order exponential equation with a pair of repeated eigenvalues, but does not require the blood input function and the fraction of blood parameters explicitly. Thus, the model can be used in cases when we wish to have the robustness and advantages of compartmental modeling, but no blood input function measurement is available. The test results show that the added error in the TACs of not knowing the blood input is reduced in comparison with the spline-based TAC representation. The method can be applied in reference tissue analysis and in image-derived input function approaches.
Keyword:
Positron emission tomography
Compartmental models
Blood input function
Dynamic reconstruction
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Biomedical Signal Processing and Control 封面图
Biomedical Signal Processing and Control
IF:
4.9
论文数:
1.0W
被引数:
2.4W

机构

B
budapest university of technology & economics
学者数:
5.7K
论文数: 5.1K
被引数: 1
引用论文

引用论文

4D image reconstruction for emission tomography
err2014-10-31
err100
errOAAI
errReader, Andrew J.; Verhaeghe, Jeroen
err分享
err收藏
Combining Field and Simulation Studies to Improve Fertilizer Recommendations for Irrigated Rice in Burkina Faso
err2005-09-01
err0
PREAI
errZ. Segda; S. M. Haefele; M. C. S. Wopereis; M. P. Sedogo; S. Guinko
err分享
err收藏
Correction: Nuclear Translocation of Jacob in Hippocampal Neurons after Stimuli Inducing Long-Term Potentiation but Not Long-Term Depression
err2011-03-01
err0
errOAAI
errThomas Behnisch; PingAn YuanXiang; Philipp Bethge; Suhel Parvez; Ying Chen; Jin Yu; Anna Karpova; Julietta U. Frey; Marina Mikhaylova; Michael R. Kreutz
err分享
err收藏
err分享
err收藏
Robust compartmental model fitting in direct emission tomography reconstruction
err2021-02-06
err2
errOAAI
errSzirmay-Kalos, Laszlo; Kacso, Agota; Magdics, Milan; Toth, Balazs
err分享
err收藏
Performance Optimization for the XAM Hybrid Electric Vehicle Prototype
err2012-04-16
err0
PREAI
errMassimiliana Carello; Nicoletta Filippo; Roberto d'Ippolito
err分享
err收藏
Non-invasive kinetic modelling of PET tracers with radiometabolites using a constrained simultaneous estimation method: evaluation with 11C-SB201745
err2018-07-03
err17
errOAAI
errSari, Hasan; Erlandsson, Kjell; Marner, Lisbeth; Law, Ian; Larsson, Henrik B. W.; Thielemans, Kris; Ourselin, Sebastien; Arridge, Simon; Atkinson, David; Hutton, Brian F.
err分享
err收藏
学者 查看更多内容