arrow
返回

Directed graph based image registration

delete2012-03-01
delete12
delete
OA
AI
H
Hongjun Jia
G
Guorong Wu
王茜 封面图
王茜 (Qian Wang)
Y
Yaping Wang
M
Minjeong Kim
D
Dinggang Shen *
DOI:10.1016/j.compmedimag.2011.09.001delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
In this paper, a novel image registration method is proposed to achieve accurate registration between images having large shape differences with the help of a set of appropriate intermediate templates. We first demonstrate that directionality is a key factor in both pairwise image registration and groupwise registration, which is defined in this paper to describe the influence of the registration direction and paths on the registration performance. In our solution, the intermediate template selection and intermediate template guided registration are two coherent steps with directionality being considered. To take advantage of the directionality, a directed graph is built based on the asymmetric distance defined on all ordered image pairs in the image population, which is fundamentally different from the undirected graph with symmetric distance metrics in all previous methods, and the shortest distance between template and subject on the directed graph is calculated. The allocated directed path can be thus utilized to better guide the registration by successively registering the subject through the intermediate templates one by one on the path towards the template. The proposed directed graph based solution can also be used in groupwise registration. Specifically, by building a minimum spanning arborescence (MSA) on the directed graph, the population center, i.e., a selected template, as well as the directed registration paths from all the rest of images to the population center, is determined simultaneously. The performance of directed graph based registration algorithm is demonstrated by the spatial normalization on both synthetic dataset and real brain MR images. It is shown that our method can achieve more accurate registration results than both the undirected graph based solution and the direct pairwise registration. (C) 2011 Elsevier Ltd. All rights reserved.
Keyword:
Image registration
Directionality
Directed graph
Minimum spanning arborescence (MSA)
Intermediate templates
Groupwise registration
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Computerized Medical Imaging and Graphics 封面图
Computerized Medical Imaging and Graphics
IF:
4.9
论文数:
2.4K
被引数:
5.0K

机构

U
university of north carolina
学者数:
7.4W
论文数: 6.5W
被引数: 93
引用论文

引用论文

Neurovascular coupling and distribution of cerebral blood flow during exercise
err2011-06-01
err0
PREAI
errC.K. Willie; E.C. Cowan; P.N. Ainslie; C.E. Taylor; K.J. Smith; P.Y.W. Sin; Y.C. Tzeng
err分享
err收藏
MATCHING OF TOMOGRAPHIC SLICES FOR INTERPOLATION
err1992-01-01
err131
PREAI
errGOSHTASBY, A; TURNER, DA; ACKERMAN, LV
err分享
err收藏
学者 查看更多内容