arrow
返回

Efficient array design for sonotherapy

delete2008-06-30
delete41
delete
OA
AI
D
Douglas N. Stephens *
D
Dustin E. Kruse
A
A.S. Ergun
S
Stephen Barnes
X
Xiaofang Lu
K
Katherine W. Ferrara
DOI:10.1088/0031-9155/53/14/014delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
New linear multi-row, multi-frequency arrays have been designed, constructed and tested as fully operational ultrasound probes to produce confocal imaging and therapeutic acoustic intensities with a standard commercial ultrasound imaging system. The triple-array probes and imaging system produce high quality B-mode images with a center row imaging array at 5.3 MHz and sufficient acoustic power with dual therapeutic arrays to produce mild hyperthermia at 1.54 MHz. The therapeutic array pair in the first probe design (termed G3) utilizes a high bandwidth and peak pressure, suitable for mechanical therapies. The second multi-array design ( termed G4) has a redesigned therapeutic array pair which is optimized for a high time-averaged power output suitable for mild hyperthermia applications. The 'thermal therapy' design produces more than 4 W of acoustic power from the low-frequency arrays with only a 10.5 degrees C internal rise in temperature after 100 s of continuous use with an unmodified conventional imaging system or substantially longer operation at lower acoustic power. The low-frequency arrays in both probe designs were examined and contrasted for real power transfer efficiency with a KLM model which includes all lossy contributions in the power delivery path from system transmitters to the tissue load. Laboratory verification was successfully performed for the KLM-derived estimates of transducer parallel model acoustic resistance and dissipation resistance, which are the critical design factors for acoustic power output and undesired internal heating, respectively.
Keyword:
PIEZOELECTRIC TRANSDUCER
ULTRASONIC TRANSDUCER
DRUG-DELIVERY
LIPOSOMES
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Physics in Medicine and Biology 封面图
Physics in Medicine and Biology
IF:
3.4
论文数:
1.4W
被引数:
3.1W

机构

S
siemens ag
学者数:
5.6K
论文数: 4.6K
被引数: 3
U
university of california davis
学者数:
3.4W
论文数: 2.6W
被引数: 45
University of California System 封面图
University of California System
学者数:
37.7W
论文数: 33.8W
被引数: 6.6K
学者 查看更多机构
引用论文

引用论文

err分享
err收藏
err分享
err收藏
err分享
err收藏
Pulsed-high intensity focused ultrasound and low temperature sensitive liposomes for enhanced targeted drug delivery and antitumor effect
err2007-05-01
err468
errOAAI
errDromi, Sergio; Frenkel, Victor; Luk, Alfred; Traughber, Bryan; Angstadt, Mary; Bur, Monica; Poff, Jason; Xie, Jianwu; Libutti, Steven K.; Li, King C. P.; Wood, Bradford J.
err分享
err收藏
Selective imaging of adherent targeted ultrasound contrast agents
err2007-03-20
err72
errOAAI
errZhao, S.; Kruse, D. E.; Ferrara, K. W.; Dayton, P. A.
err分享
err收藏
Liposomes - Opportunities in drug delivery
errDRUGS
IF14.4
err1997-01-01
err279
PREAI
errAllen, TM
err分享
err收藏
学者 查看更多内容