arrow
返回

Efficient uncertainty quantification for Monte Carlo dose calculations using importance (re-)weighting

delete2021-10-07
delete4
delete
OA
AI
P
Pia Stammer *
L
Lucas Burigo
O
Oliver Jäkel
M
Martin Frank
N
Niklas Wahl
DOI:10.1088/1361-6560/ac287fdelete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Objective. To present an efficient uncertainty quantification method for range and set-up errors in Monte Carlo (MC) dose calculations. Further, we show that uncertainty induced by interplay and other dynamic influences may be approximated using suitable error correlation models. Approach. We introduce an importance (re-)weighting method in MC history scoring to concurrently construct estimates for error scenarios, the expected dose and its variance from a single set of MC simulated particle histories. The approach relies on a multivariate Gaussian input and uncertainty model, which assigns probabilities to the initial phase space sample, enabling the use of different correlation models. Through modification of the phase space parameterization, accuracy can be traded between that of the uncertainty or the nominal dose estimate. Main results. The method was implemented using the MC code TOPAS and validated for proton intensity-modulated particle therapy (IMPT) with reference scenario estimates. We achieve accurate results for set-up uncertainties (gamma (2 mm/2%) >= 99.01% (E[ d ]), gamma (2 mm/2%) >= 98.04% (sigma( d ))) and expectedly lower but still sufficient agreement for range uncertainties, which are approximated with uncertainty over the energy distribution. Here pass rates of 99.39% (E[ d ])/ 93.70% (sigma( d )) (range errors) and 99.86% (E[ d ])/ 96.64% (sigma( d )) (range and set-up errors) can be achieved. Initial evaluations on a water phantom, a prostate and a liver case from the public CORT dataset show that the CPU time decreases by more than an order of magnitude. Significance. The high precision and conformity of IMPT comes at the cost of susceptibility to treatment uncertainties in particle range and patient set-up. Yet, dose uncertainty quantification and mitigation, which is usually based on sampled error scenarios, becomes challenging when computing the dose with computationally expensive but accurate MC simulations. As the results indicate, the proposed method could reduce computational effort while also facilitating the use of high-dimensional uncertainty models.
Keyword:
proton therapy
uncertainty
setup error
range error
Monte Carlo
importance sampling
intensity modulated particle therapy (IMPT)

期刊

Physics in Medicine and Biology 封面图
Physics in Medicine and Biology
IF:
3.4
论文数:
1.4W
被引数:
3.1W

机构

K
karlsruhe institute of technology
学者数:
2.0W
论文数: 1.5W
被引数: 23
H
Helmholtz Association
学者数:
13.2W
论文数: 10.7W
被引数: 145
引用论文

引用论文

Entanglement of two blocks of spins in the critical Ising model
err2008-11-03
err0
errOAAI
errP. Facchi; G. Florio; C. Invernizzi; S. Pascazio
err分享
err收藏
A beam source model for scanned proton beams
err2007-05-10
err31
PREAI
errKimstrand, Peter; Traneus, Erik; Ahnesjo, Anders; Grusell, Erik; Glimelius, Bengt; Tilly, Nina
err分享
err收藏
Analytical probabilistic modeling of dose-volume histograms
err2020-09-09
err6
errOAAI
errWahl, Niklas; Hennig, Philipp; Wieser, Hans-Peter; Bangert, Mark
err分享
err收藏
Monte Carlo dose calculations for spot scanned proton therapy
err2005-02-18
err87
PREAI
errTourovsky, A; Lomax, AJ; Schneider, U; Pedroni, E
err分享
err收藏
Efficacy of adjuvant chemotherapy for completely resected stage IB non-small cell lung cancer: a retrospective study
err2018-04-01
err0
errOAAI
errHye Jung Park; Heae Surng Park; Yoon Jin Cha; Sungsoo Lee; Hei-Cheul Jeung; Jae Yong Cho; Hyung Jung Kim; Min Kwang Byun
err分享
err收藏
err分享
err收藏
学者 查看更多内容