Previous investigations on electrocapillary instability in a liquid metal confined in a circular cylindrical vessel are extended to annular geometry. The number of peaks arising on an initially flat surface when a strong electric field acts on it is determined in terms of the inner and outer ring radii, as well as the critical electric field needed for destabilization. The limiting case of an infinite, straight recipient is independently solved and compared to the annular geometry results for appropriate values of these radii. Experimental observations with mercury are included and confronted to the theory. (C) 1997 American Institute of Physics.