arrow
返回

Electrode Configuration for Auditory Brainstem Response Audiometry

delete1992-03-01
delete0
PRE
AI
DOI:10.1044/1059-0889.0102.63delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
A vertical recording montage (C z to the seventh cervical vertebra or C 7 ) has been shown to yield significantly lower auditory brainstem response (ABR) threshold when compared with a horizontal or anterior-posterior montage (Sininger & Don, 1989). The present study further examines the relationship between electrode placement and the amplitude of the ABR to low-level stimuli. Four electrode arrays were compared—the commonly-used clinical configuration of forehead to ipsilateral mastoid, the vertical array from the previous study (C z to C 7 ), and two additional montages employing linked mastoids as reference to either the vertex or forehead electrode. ABRs were recorded simultaneously in four channels in response to 8000 click stimuli at 10, 20, and 30 dB SL from 9 male and 9 female adult subjects with normal hearing. The effect of electrode channel was significant at <.0001, with the vertical channel revealing the largest wave V amplitudes at all stimulus levels. Female subjects, as expected, produced larger ABR amplitudes than male subjects in all recording conditions, but electrode-channel effects were independent of gender.
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

暂无期刊信息

机构

暂无机构信息
引用论文

引用论文

暂无论文信息