返回
Electroosmotic flow patterning using microfluidic delay loops
DOI:10.1039/b609423f.png)
摘要
En 中文
A theoretical and experimental investigation of alternating electroosmotic flow patterns by means of specially designed delay loops is presented. Using elementary methods of compact network modeling and detailed FEM simulations the flow behavior and, in particular, the rearrangement of sample plugs is modeled. The proposed designs rely on flow splitting in combination with electroosmotic delay loops leading to a runtime difference or phase shift between two sub-streams. Due to this phase shift, a new fluid interface is generated at the merging point. The approach is experimentally validated by injection of a Rhodamine 6G solution into an aqueous sodium tetraborate buffer.
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。