返回
Endoscope sampling and culturing methods
DOI:10.1016/j.jhin.2024.03.017.png)
摘要
En 中文
Background: Contamination rates reported in the literature for patient-ready flexible endoscopes vary from 0.4% to 49%. Unfortunately, the comparison and interpretation of these results is almost impossible since several factors including sampling and culturing methods, target levels for contamination, or definition of indicator micro-organisms vary widely from one study to the other. Aim: To compare the efficacy of six duodenoscope sampling and culturing methods by means of extraction efficacy comparison, while at the same time identifying key parameters that provide optimal microbial recovery. Methods: The duodenoscope sample extraction efficacy of each method was assessed using the repetitive recovery method described in ISO 11737-1: 2018. Findings: Mean overall bioburden extraction efficacy varied from 1% for the Australian method to 39% for the French one. The lowest endoscope sample extraction efficacy was associated with the absence of any neutralizer, friction, or tensioactive agent, and when only a small portion of the sampling solution collected was inoculated on to culture media. The efficacy of the sampling and culturing methods also varied according to the nature of micro-organisms present in the endoscope, and the time between sampling and culturing. Conclusion: This study supports the need for a harmonized and standardized sampling and culturing method for flexible endoscopes. (c) 2024 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Keyword:
Endoscope
Sampling method
Culturing method
Contamination rate
Extraction efficacy
期刊
IF:
3.1
论文数:
7.5K
被引数:
1.0W
机构
暂无机构信息
引用论文
Reprocessing of flexible endoscopes and endoscopic accessories used in gastrointestinal endoscopy: Position Statement of the European Society of Gastrointestinal Endoscopy (ESGE) and European Society of Gastroenterology Nurses and Associates (ESGENA) - Update 2018
ENDOSCOPY
IF12.8
Handle grip span for optimising finger-specific force capability as a function of hand size
Ergonomics
IF0
Endoscope disinfection and its pitfalls - requirement for retrograde surveillance cultures
ENDOSCOPY
IF12.8
Active Process Control in Pharmaceutical Continuous Manufacturing – The Quality by Control (QbC) Paradigm制药连续制造中的主动过程控制——基于控制的质量(QbC)范式
Prevention of multidrug-resistant infections from contaminated duodenoscopes: Position Statement of the European Society of Gastrointestinal Endoscopy (ESGE) and European Society of Gastroenterology Nurses and Associates (ESGENA)
ENDOSCOPY
IF12.8