arrow
返回

Engineering sampling microneedles for biomolecules sensing

delete2024-11-01
delete0
PRE
AI
Y
Yun Cheng
X
Xi Luan
J
Jiawu Weng
L
Lexiang Zhang
F
Fangfu Ye *
DOI:10.1016/j.cej.2024.156130delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Interstitial fluid (ISF), located in superficial tissues, has garnered significant attention for its rich composition of biological substances. Sampling microneedles (MNs) are particularly well-suited for sensing these biomolecules due to their minimally invasive nature, reduced discomfort, in-situ diagnostic capabilities, and compatibility with various technologies. This review aims to summarize up-to-date advancements in the customization of MNs for emerging biosensing technologies targeting ISF biomolecules. First, the sensing applications of different types of MNs are comprehensively introduced, with a focus on tailoring biorecognition components or integrating biosensors to analyze nucleic acids, proteins and exosomes, lactate, glucose, various ions, and other small molecules. We then specialize in different sensing modes, including offline, optical, and electrochemical approaches, along with examination techniques such as quantitative fluorescence analysis, visual result interpretation, and flexible electronics customization. Furthermore, wearable and implantable MN devices for closedloop and continuous monitoring are highlighted, emphasizing their roles in accurate therapeutic drug management for localized extra-organ diseases, real-time treatment progress monitoring, and disease prognosis. Moreover, we briefly discuss MN-based electrophysiological measurements and other promising applicable sensing technologies currently in the proof-of-concept stage with buffer or surrogate solutions. Finally, the challenges and future perspectives of MNs for ISF biomolecular sensing are outlined.
Keyword:
Microneedle
Biosensing
Biomolecules
Interstitial fluid
Detection

期刊

Chemical Engineering Journal 封面图
Chemical Engineering Journal
IF:
13.2
论文数:
7.6W
被引数:
48.5W

机构

W
Wenzhou Medical University
学者数:
3.3W
论文数: 1.6W
被引数: 3.0W
引用论文

引用论文

A Wearable Touch-Activated Device Integrated with Hollow Microneedles for Continuous Sampling and Sensing of Dermal Interstitial Fluid与空心微针集成的可穿戴触摸激活设备,用于连续采样和感测皮肤间质液
err2023-11-23
err17
errOAAI
errAbbasiasl, Taher; Mirlou, Fariborz; Mirzajani, Hadi; Bathaei, Mohammad Javad; Istif, Emin; Shomalizadeh, Narges; Cebecioglu, Ruemeysa Emine; Ozkahraman, Ecem Ezgi; Yener, Umut Can; Beker, Levent
err分享
err收藏
err分享
err收藏
Integrated hollow microneedle-optofluidic biosensor for therapeutic drug monitoring in sub-nanoliter volumes
err2016-07-06
err46
errOAAI
errRanamukhaarachchi, Sahan A.; Padeste, Celestino; Dubner, Matthias; Hafeli, Urs O.; Stoeber, Boris; Cadarso, Victor J.
err分享
err收藏
err分享
err收藏
Microneedle pH Sensor: Direct, Label-Free, Real-Time Detection of Cerebrospinal Fluid and Bladder pH微针pH传感器: 直接、无标记、实时检测脑脊液和膀胱pH
err2017-06-20
err70
PREAI
errMani, Ganesh Kumar; Miyakoda, Kousei; Saito, Asuka; Yasoda, Yutaka; Kajiwara, Kagemasa; Kimura, Minoru; Tsuchiya, Kazuyoshi
err分享
err收藏
Evaluation of symptoms and QOL with calcium alginate versus chitin-coated gauze for middle meatus packing after endoscopic sinus surgery
err2012-02-01
err0
PREAI
errTetsushi Okushi; Mamoru Yoshikawa; Nobuyoshi Otori; Yoshinori Matsuwaki; Daiya Asaka; Tsugihisa Nakayama; Tadamitsu Morimoto; Hiroshi Moriyama
err分享
err收藏
Multifunctional Inverse Opal Microneedle Arrays for Drug Delivery and Monitoring
errSMALL
IF12.1
err2022-06-09
err23
PREAI
errLu, Minhui; Fan, Lu; Chen, Hanxu; Zhang, Zhuohao; Zhao, Yuanjin
err分享
err收藏
Skin preparation-free, stretchable microneedle adhesive patches for reliable electrophysiological sensing and exoskeleton robot control无皮肤准备,可拉伸微针粘合剂贴片,用于可靠的电生理传感和外骨骼机器人控制
err2024-01-19
err17
errOAAI
errKim, Heesoo; Lee, Juhyun; Heo, Ung; Jayashankar, Dhileep Kumar; Agno, Karen-Christian; Kim, Yeji; Kim, Choong Yeon; Oh, Youngjun; Byun, Sang-Hyuk; Choi, Bohyung; Jeong, Hwayeong; Yeo, Woon-Hong; Li, Zhuo; Park, Seongjun; Xiao, Jianliang; Kim, Jung; Jeong, Jae-Woong
err分享
err收藏
Highly stretchable and customizable microneedle electrode arrays for intramuscular electromyography用于肌内肌电图的高度可拉伸和可定制的微针电极阵列
err2024-05-03
err4
errOAAI
errZhao, Qinai; Gribkova, Ekaterina; Shen, Yiyang; Cui, Jilai; Naughton, Noel; Liu, Liangshu; Seo, Jaemin; Tong, Baixin; Gazzola, Mattia; Gillette, Rhanor; Zhao, Hangbo
err分享
err收藏
学者 查看更多内容