Enhancing Structuree-Function Correlations in Glaucoma with Customized Spatial Mapping

delete2015-08-01
delete37
PRE
AI
S
Shonraj Ballae Ganeshrao
A
Andrew Turpin
J
Jonathan Denniss
A
Allison M. McKendrick *
DOI:10.1016/j.ophtha.2015.04.021delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Purpose: To determine whether the structure-function relationship in glaucoma can be strengthened by using more precise structural and functional measurements combined with individualized structure-function maps and custom sector selection on the optic nerve head (ONH). Design: Cross-sectional study. Participants: One eye of each of 23 participants with glaucoma. Methods: Participants were tested twice. Visual fields were collected on a high-resolution 3 degrees x 3 degrees grid (164 locations) using a Zippy Estimation by Sequential Testing test procedure with uniform prior probability to improve the accuracy and precision of scotoma characterization relative to standard methods. Retinal nerve fiber layer (RNFL) thickness was measured using spectral-domain optical coherence tomography (OCT; 4 scans, 2 per visit) with manual removal of blood vessels. Individualized maps, based on biometric data, were used. To customize the areas of the ONH and visual field to correlate, we chose a 30 degrees sector centered on the largest defect shown by OCT and chose visual field locations using the individualized maps. Baseline structure-function correlations were calculated between 24-2 locations (n = 52) of the first tested visual field and RNFL thickness from 1 OCT scan, using the sectors of the Garway-Heath map. We added additional data (averaged visual field and OCT, additional 106 visual field locations and OCT without blood vessels, individualized map, and customized sector) and recomputed the correlations. Main Outcome Measures: Spearman correlation between structure and function. Results: The highest baseline correlation was 0.52 (95% confidence interval [CI], 0.13-0.78) in the superior temporal ONH sector. Improved measurements increased the correlation marginally to 0.58 (95% CI, 0.21-0.81). Applying the individualized map to the large, predefined ONH sectors did not improve the correlation; however, using the individualized map with the single 30 degrees ONH sector resulted in a large increase in correlation to 0.77 (95% CI, 0.47-0.92). Conclusions: Using more precise visual field and OCT measurements did not improve structure-function correlation in our cohort, but customizing the ONH sector and its associated visual field points substantially improved correlation. We suggest using customized ONH sectors mapped to individually relevant visual field locations to unmask localized structural and functional loss. (C) 2015 by the American Academy of Ophthalmology.
Keyword:
RETINAL NERVE-FIBER
OPTICAL COHERENCE TOMOGRAPHY
STANDARD AUTOMATED PERIMETRY
FALSE-NEGATIVE RESPONSES
VISUAL-FIELD
LAYER THICKNESS
FULL THRESHOLD
ATTENUATION COEFFICIENT
BUNDLE TRAJECTORIES
SAMPLING DENSITY
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Ophthalmology 封面图
Ophthalmology
IF:
9.5
论文数:
1.3W
被引数:
4.4W

机构

U
university of melbourne
学者数:
5.7W
论文数: 5.4W
被引数: 69
引用论文

引用论文

Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT
err2004-06-01
err493
errOAAI
errPaunescu, LA; Schuman, JS; Price, LL; Stark, PC; Beaton, S; Ishikawa, H; Wollstein, G; Fujimoto, JG
err分享
err收藏
err分享
err收藏
High spatial resolution automated perimetry in glaucoma
err1997-06-01
err45
errOAAI
errWestcott, MC; McNaught, AI; Crabb, DP; Fitzke, FW; Hitchings, RA
err分享
err收藏
err分享
err收藏
Application of Aptamer Identification Technology in Rapid Analysis of Mycotoxins
err2013-02-01
err0
PREAI
errXi-Hui YANG; Wei-Jun KONG; Mei-Hua YANG; Ming ZHAO; Zhen OUYANG
err分享
err收藏
'Structure-function relationship' in glaucoma: past thinking and current concepts
err2012-04-12
err190
errOAAI
errMalik, Rizwan; Swanson, William H.; Garway-Heath, David F.
err分享
err收藏
学者 查看更多内容