Kinetic and dynamic motion analysis provides quantitative, functional assessments of human ability that are unobtainable through static imaging methods or subjective surveys. While biomechanics facilities are equipped to perform this measurement and analysis, the clinical translation of these methods is limited by the specialized skills and equipment needed. This paper presents and validates a method for estimating dynamic effects such as joint torques and body momenta using a single depth camera. An allometrically scaled, sagittal plane dynamic model is used to estimate the joint torques at the ankles, knees, hips, and low back, as well as the torso momenta, and shear and normal loads at the L5-S1 disk. These dynamic metrics are applied to the sit-to-stand motion and validated against a gold-standard biomechanical system consisting of full-body active motion-capture and force-sensing systems. The metrics obtained from the proposed method were found to have excellent concordance with peak metrics that are consistent with prior biomechanical studies. This suggests the feasibility of using this system for rapid clinical assessment, with applications in diagnostics, longitudinal tracking, and quantifying patient recovery.