Exploring shear-wave elastography and apparent diffusion coefficient in breast lesion characterization: diagnostic accuracy and inter-modality correlation

delete2026-05-30
delete0
PRE
AI
F
Francesco Marcello Aricò *
A
Antonio Portaluri
P
Pasquale Arena
C
Carmelo Sofia
E
Elvira Condorelli
F
Francesca Catanzariti
V
Valeria Zuccalà
M
Massimiliano Berretta
G
Giorgio Ascenti
M
Maria Adele Marino
DOI:10.1007/s11547-026-02228-7delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
To compare shear-wave elastography (SWE) and diffusion-weighted imaging (DWI)-derived apparent diffusion coefficient (ADC) values in the differentiation of benign and malignant breast lesions, and to assess the correlation and potential interchangeability between these imaging biomarkers. In this retrospective study, 53 female patients (mean age: 55.2 ± 11.7 years) with biopsy-proven BI-RADS 4 or 5 breast lesions underwent both SWE and breast MRI, including DWI. SWE parameters (Emax, Emean, Emin) and ADC values were quantitatively analyzed and compared using Mann–Whitney U tests. Diagnostic performance was evaluated via ROC analysis. Correlation and interchangeability between SWE and ADC were assessed using Spearman’s rank correlation, regression analysis, and Bland–Altman plots. Among 53 lesions (26 malignant, 27 benign), SWE Emax demonstrated the best diagnostic performance among SWE parameters (AUC = 0.74), with an optimal cut-off of > 69.47 kPa (sensitivity: 62%, specificity: 81%). ADC values achieved superior diagnostic accuracy (AUC = 0.94), with a cut-off of < 1182 × 10⁻⁶ mm2/s (sensitivity: 92%, specificity: 93%). A moderate inverse correlation was found between SWE Emax and ADC values (ρ = − 0.39, p = 0.004), but regression (R2 = 0.19) and Bland–Altman analysis (limits of agreement ± 46%) indicated poor agreement and limited predictive utility. These findings confirm that as tissue stiffness increases, water molecule diffusivity decreases. While SWE Emax and ADC values show a statistically significant inverse correlation, they are not interchangeable in clinical practice. ADC demonstrated superior performance as a standalone parameter for lesion characterization, whereas SWE retains value as a complementary tool within a multiparametric ultrasound approach. Further studies are warranted to confirm these findings in larger cohorts.
Keywords:
Breast cancer
Shear-wave elastography
Apparent diffusion coefficient
Multiparametric imaging
Ultrasound
MRI

Journal

La radiologia medica cover
La radiologia medica
IF:
4.8
Papers:
206
Citations:
0

Organization

G
Gaetano Barresi
Scholars:
16
Papers: 6
Citations: 0
A
aou g. martino hospital
Scholars:
2
Papers: 2
Citations: 0
P
policlinico g. martino
Scholars:
16
Papers: 2
Citations: 0
Cited Papers

Cited Papers

Citing Papers

Citing Papers