arrow
返回

Fast and efficient fully 3D PET image reconstruction using sparse system matrix factorization with GPU acceleration

delete2011-10-04
delete77
delete
OA
AI
周
周建 (Jian Zhou) *
J
Jinyi Qi
DOI:10.1088/0031-9155/56/20/015delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Statistically based iterative image reconstruction has been widely used in positron emission tomography (PET) imaging. The quality of reconstructed images depends on the accuracy of the system matrix that defines the mapping from the image space to the data space. However, an accurate system matrix is often associated with high computation cost and huge storage requirement. In this paper, we present a method to address this problem using sparse matrix factorization and graphics processor unit (GPU) acceleration. We factor the accurate system matrix into three highly sparse matrices: a sinogram blurring matrix, a geometric projection matrix and an image blurring matrix. The geometrical projection matrix is precomputed based on a simple line integral model, while the sinogram and image blurring matrices are estimated from point-source measurements. The resulting factored system matrix has far less nonzero elements than the original system matrix, which substantially reduces the storage and computation cost. The smaller matrix size also allows an efficient implementation of the forward and backward projectors on a GPU, which often has a limited memory space. Our experimental studies show that the proposed method can dramatically reduce the computation cost of high-resolution iterative image reconstruction, while achieving better performance than existing factorization methods.
Keyword:
POINT-SPREAD FUNCTION
ITERATIVE RECONSTRUCTION
SPACE
IMPACT
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Physics in Medicine and Biology 封面图
Physics in Medicine and Biology
IF:
3.4
论文数:
1.4W
被引数:
3.1W

机构

University of California System 封面图
University of California System
学者数:
37.7W
论文数: 33.8W
被引数: 6.6K
引用论文

引用论文

Application and Evaluation of a Measured Spatially Variant System Model for PET Image Reconstruction
err2010-03-01
err190
errOAAI
errAlessio, Adam M.; Stearns, Charles W.; Tong, Shan; Ross, Steven G.; Kohlmyer, Steve; Ganin, Alex; Kinahan, Paul E.
err分享
err收藏
Non-Gaussian space-variant resolution modelling for list-mode reconstruction
err2010-08-11
err61
PREAI
errCloquet, C.; Sureau, F. C.; Defrise, M.; Van Simaeys, G.; Trotta, N.; Goldman, S.
err分享
err收藏
Modeling and incorporation of system response functions in 3-D whole body PET
err2006-07-01
err162
PREAI
errAlessio, Adam M.; Kinahan, Paul E.; Lewellen, Thomas K.
err分享
err收藏
Single scan parameterization of space-variant point spread functions in image space via a printed array: the impact for two PET/CT scanners
err2011-04-13
err49
errOAAI
errKotasidis, F. A.; Matthews, J. C.; Angelis, G. I.; Noonan, P. J.; Jackson, A.; Price, P.; Lionheart, W. R.; Reader, A. J.
err分享
err收藏
MicroPET II: design, development and initial performance of an improved microPET scanner for small-animal imaging
err2003-05-20
err250
errOAAI
errTai, YC; Chatziioannou, AF; Yang, YF; Silverman, RW; Meadors, K; Siegel, S; Newport, DF; Stickel, JR; Cherry, SR
err分享
err收藏
Multi-ray-based system matrix generation for 3D PET reconstruction
err2008-11-12
err93
PREAI
errMoehrs, Sascha; Defrise, Michel; Belcari, Nicola; Del Guerra, Alberto; Bartoli, Antonietta; Fabbri, Serena; Zanetti, Gianluigi
err分享
err收藏
High-resolution 3D Bayesian image reconstruction using the microPET small-animal scanner
err1999-01-01
err588
PREAI
errQi, JY; Leahy, RM; Cherry, SR; Chatziioannou, A; Farquhar, TH
err分享
err收藏
学者 查看更多内容