arrow
返回

Flow-batch miniaturization

delete2011-10-01
delete24
delete
OA
AI
S
Severino S. Monte-Filho
M
Marcelo B. Lima
S
Stéfani Iury E. Andrade
D
David P. Harding
Y
Yebá N.M. Fagundes
S
Sérgio Ricardo Bezerra dos Santos
S
Sherlan G. Lemos
M
Mário César Ugulino de Araújo *
DOI:10.1016/j.talanta.2011.08.063delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
This study introduces the first micro-flow-batch analyzer (mu FBA). A simple, low-cost, deep urethane-acrylate photo-resist ultraviolet-lithographic technique was used in its development. Details of the microfabrication process are presented including; the use of two superimposed photo-masks to improve the micro-channel and stop chamber border definition, as well as integration of an LED/phototransistor photometric pair, while using an open nylon-thread (fishing line) micro-mixing system for solutions homogenization. The system was used for photometric determination of Fe(II) in oral solution iron supplements employing the well-known 1,10-phenanthroline method, with instantaneously prepared micro-chamber calibration solutions. All analytical processes were accomplished by simply changing the timing parameters in the control software. It must be emphasized here that there was no outside preparation of the standard calibration solutions; the mixing was all done in-chamber/in-line, with all solutions maintained flowing while being proportioned for the measurement processes. The mu FBA results were acceptable when compared to the reference method, and comparable to normal flow-batch systems. It was possible both to project and build a low-cost probe with high sample throughput (about 120 h(-1)), low relative standard deviations (about 1.1%), and reduced reagent consumption (30 times less than the reference method). The mu FBA system based on urethane-acrylate presented satisfactory physical and chemical properties while keeping the flexibility, versatility, robustness, and multi-task characteristics of normal flow-batch analyzers. The mu FBA system contributes to the advance of micro-analytical instrumentation, while realizing the basic principles of Green Chemistry. (C) 2011 Elsevier B.V. All rights reserved.
Keyword:
Flow-batch analyzer
Urethane-acrylate photo-resist
Microfabrication
Deep ultraviolet-lithography
UV-vis spectrophotometry
Determination of Fe(II)
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Talanta 封面图
Talanta
IF:
6.1
论文数:
2.6W
被引数:
6.3W

机构

U
universidade federal da paraiba
学者数:
6.4K
论文数: 4.2K
被引数: 3
I
instituto federal da paraiba (ifpb)
学者数:
263
论文数: 199
被引数: 0
引用论文

引用论文

Flow-batch technique for the simultaneous enzymatic determination of levodopa and carbidopa in pharmaceuticals using PLS and successive projections algorithm
errTALANTA
IF6.1
err2008-05-30
err50
errOAAI
errGruenhut, Marcos; Centurion, Maria E.; Fragoso, Wallace D.; Almeida, Luciano R.; U. de Arajo, Mario C.; Fernandez Band, Beatriz S.
err分享
err收藏
Rapid fabrication of microfluidic devices in poly(dimethylsiloxane) by photocopying
err2001-01-01
err93
PREAI
errTan, AM; Rodgers, K; Murrihy, JP; O'Mathuna, C; Glennon, JD
err分享
err收藏
Relationship between the expressions of LMP1 and E-cadherin/β-catenin in nasopharyngeal carcinoma
err2002-09-01
err0
PREAI
errSu-xia Lin; Yong-sheng Zong; Bing Chu; Bi-ling Zhong; Zhi Li; Ying-jie Liang; Han-liang Lin
err分享
err收藏
err分享
err收藏
Automatic determination of chlorine without standard solutions using a biamperometric flow-batch analysis system使用双安培流批分析系统在没有标准溶液的情况下自动测定氯
errTALANTA
IF6.1
err2010-04-01
err23
errOAAI
errNascimento, Valberes B.; Selva, Thiago M. G.; Coelho, Elaine C. S.; Santos, Francyana P.; Antonio, Jadielson L. S.; Silva, Jose R.; Gaiao, Edvaldo N.; Araujo, Mario C. U.
err分享
err收藏
UV laser machined polymer substrates for the development of microdiagnostic systems
err1997-06-01
err539
PREAI
errRoberts, MA; Rossier, JS; Bercier, P; Girault, H
err分享
err收藏
Simple and rapid methods for the fabrication of polymeric and glass chips for using in analytical chemistry
err2007-04-01
err8
PREAI
errSorouraddin, Mohammad H.; Amjadi, Mohammad; Safi-Shalamzari, Mohammad
err分享
err收藏
Spectrophotometric cocaine determination in a biphasic medium employing flow-batch sequential injection analysis
err2008-11-01
err21
PREAI
errda Silva, Maria Jose; dos Anjos, Edijane V.; Honorato, Ricardo S.; Pimentel, Maria Fernanda; Paim, Ana Paula S.
err分享
err收藏
Robust flow-batch coulometric/biamperometric titration system: Determination of bromine index and bromine number of petrochemicals
err2007-09-01
err22
PREAI
errPasquini, Celio; de Aquino, Emerson Vidal; Reboucas, Marcio das Virgens; Gonzaga, Fabiano Barbieri
err分享
err收藏
err分享
err收藏
学者 查看更多内容