返回
Flow-batch miniaturization
DOI:10.1016/j.talanta.2011.08.063.png)
摘要
En 中文
This study introduces the first micro-flow-batch analyzer (mu FBA). A simple, low-cost, deep urethane-acrylate photo-resist ultraviolet-lithographic technique was used in its development. Details of the microfabrication process are presented including; the use of two superimposed photo-masks to improve the micro-channel and stop chamber border definition, as well as integration of an LED/phototransistor photometric pair, while using an open nylon-thread (fishing line) micro-mixing system for solutions homogenization. The system was used for photometric determination of Fe(II) in oral solution iron supplements employing the well-known 1,10-phenanthroline method, with instantaneously prepared micro-chamber calibration solutions. All analytical processes were accomplished by simply changing the timing parameters in the control software. It must be emphasized here that there was no outside preparation of the standard calibration solutions; the mixing was all done in-chamber/in-line, with all solutions maintained flowing while being proportioned for the measurement processes. The mu FBA results were acceptable when compared to the reference method, and comparable to normal flow-batch systems. It was possible both to project and build a low-cost probe with high sample throughput (about 120 h(-1)), low relative standard deviations (about 1.1%), and reduced reagent consumption (30 times less than the reference method). The mu FBA system based on urethane-acrylate presented satisfactory physical and chemical properties while keeping the flexibility, versatility, robustness, and multi-task characteristics of normal flow-batch analyzers. The mu FBA system contributes to the advance of micro-analytical instrumentation, while realizing the basic principles of Green Chemistry. (C) 2011 Elsevier B.V. All rights reserved.
Keyword:
Flow-batch analyzer
Urethane-acrylate photo-resist
Microfabrication
Deep ultraviolet-lithography
UV-vis spectrophotometry
Determination of Fe(II)
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
6.1
论文数:
2.6W
被引数:
6.3W
机构
引用论文
Flow-batch technique for the simultaneous enzymatic determination of levodopa and carbidopa in pharmaceuticals using PLS and successive projections algorithm
TALANTA
IF6.1
Rapid fabrication of microfluidic devices in poly(dimethylsiloxane) by photocopying
LAB ON A CHIP
IF5.4
Automatic determination of chlorine without standard solutions using a biamperometric flow-batch analysis system使用双安培流批分析系统在没有标准溶液的情况下自动测定氯
TALANTA
IF6.1
UV laser machined polymer substrates for the development of microdiagnostic systems
ANALYTICAL CHEMISTRY
IF6.7

