返回
Frequency division multiplex HPLC-MS for simultaneous analyses
DOI:10.1039/c8an02352b.png)
摘要
En 中文
Multiplex high-performance liquid chromatograph-mass spectrometry (HPLC-MS), in which multiple HPLCs and one MS are hyphenated, is an approach for high throughput analysis in HPLC-MS. A general multiplex HPLC-MS method employs a column-switching technology, and only one HPLC is connected to one MS at a time. In the present study, we propose a novel multiplex HPLC-MS system for simultaneous HPLC-MS analyses. In this study, multiple HPLCs are hyphenated with one MS without a column-switching mechanism, and a mixed-chromatogram is observed by the MS. Here, we employ a frequency division multiplexing (FDM) technique used in communication engineering to extract any chromatogram from the mixed-chromatogram. When a modulator (chopper or ion-gate type) is set between each ion source and the MS, each modulator blocks each sample stream with an individual frequency. In theory, each chromatogram can be extracted from the mixed-chromatogram via a signal processing based on a Fourier transform (FT), frequency-based signal extraction, and reversed FT. In the actual experiment, two HPLCs are hyphenated with one MS (2HPLC-1MS). The use of chopper type modulators leads to the extraction and restoration of each chromatogram from the mixed-chromatogram. However, each restored-chromatogram involves signal interference. On the other hand, the ion-gate modulation system successfully resulted in restored-chromatograms without interference. The potential of the novel multiplex HPLC-MS system based on FDM is confirmed with respect to the simultaneous and continuous analyses of plural samples.
Keyword:
SUPERCRITICAL-FLUID CHROMATOGRAPHY
LIQUID-CHROMATOGRAPHY
MASS-SPECTROMETRY
HADAMARD-TRANSFORM
SEPARATION
CAPILLARY
ELECTROCHROMATOGRAPHY
MATRICES
DESIGN
SYSTEM
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
A
IF:
3.3
论文数:
1.6W
被引数:
3.3W
机构
引用论文
Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry: A High-Throughput Platform for Metabolomics with High Data Fidelity
ANALYTICAL CHEMISTRY
IF6.7
Frequency-Modulated Continuous Flow Analysis Electrospray Ionization Mass Spectrometry (FM-CFA-ESI-MS) for Sample Multiplexing
ANALYTICAL CHEMISTRY
IF6.7
A four-column parallel chromatography system for isocratic or gradient LC/MS analyses
ANALYTICAL CHEMISTRY
IF6.7
Evaluation of a four-channel multiplexed electrospray triple quadrupole mass spectrometer for the simultaneous validation of LC/MS/MS methods in four different preclinical matrixes
ANALYTICAL CHEMISTRY
IF6.7
Online High Throughput Measurements for Fast Catalytic Reactions Using Time-Division Multiplexing Gas Chromatography
ANALYTICAL CHEMISTRY
IF6.7
Applications of Hadamard transform to gas chromatography mass spectrometry and liquid chromatography mass spectrometry
ANALYTICAL CHEMISTRY
IF6.7