arrow
返回

Frequency multiplexing enables parallel multi-sample EPR

delete2024-05-23
delete0
delete
OA
AI
C
Chun Him Lee
J
Jan G. Korvink
M
Mazin Jouda *
DOI:10.1038/s41598-024-62564-4delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Electron paramagnetic resonance (EPR) spectroscopy stands out as a powerful analytical technique with extensive applications in the fields of biology, chemistry, physics, and material sciences. It proves invaluable for investigating the molecular structure and reaction mechanisms of substances containing unpaired electrons, such as metal complexes, organic and inorganic radicals, and intermediate states in chemical reactions. However, despite their remarkable capabilities, EPR systems face significant limitations in terms of sample throughput, as current commercial systems only target the analysis of one sample at a time. Here we introduce a novel scheme for conducting ultra-high frequency continuous-wave EPR (CW EPR) targeting the EPR spectroscopy of multiple microliter volume samples in parallel. Our proof-of-principle prototype involves two decoupled detection cells equipped with high qualty factor Q = 104 solenoidal coils tuned to 488 and 589 MHz, ensuring a significant frequency gap for effective radio frequency (RF) decoupling between the channels. To further enhance electromagnetic decoupling, an orthogonal alignment of the coils was adopted. The paper further presents an innovative radiofrequency circuit concept that utilizes a single physical RF channel to simultaneously conduct parallel EPR on up to eight cells. Parallel EPR experiments on two BDPA samples, each with a sample volume of 18.3 mu L, registered signal-to-noise ratios of 255 and 252 for the two EPR measurement cells, with no observable coupling. The showcased prototype, built using cost-effective commercially available fabrication technology, is readily scalable and represents an initial step with promising potential for advancing sample screening with high-throughput parallel EPR.
Keyword:
Parallel EPR
Parallel ODNP
High-throughput
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

Advantages of Multiplexing Ability of the Orbitrap Mass Analyzer in the Multi-Mycotoxin Analysis
err2023-02-07
err5
errOAAI
errRakk, David; Kukolya, Jozsef; Skrbic, Biljana D.; Vagvolgyi, Csaba; Varga, Monika; Szekeres, Andras
err分享
err收藏
High-Throughput Two-Photon 3D Printing Enabled by Holographic Multi-Foci High-Speed Scanning通过全息多焦点高速扫描实现高通量双光子3D打印
err2024-02-20
err13
PREAI
errZhang, Leran; Wang, Chaowei; Zhang, Chenchu; Xue, Yuhang; Ye, Zhaohui; Xu, Liqun; Hu, Yanlei; Li, Jiawen; Chu, Jiaru; Wu, Dong
err分享
err收藏
err分享
err收藏
err分享
err收藏
parallel: A command for parallel computing
err2019-09-20
err9
errOAAI
errYon, George G. Vega; Quistorff, Brian
err分享
err收藏

期刊

Scientific Reports 封面图
Scientific Reports
IF:
3.9
论文数:
28.8W
被引数:
108.9W

机构

H
Helmholtz Association
学者数:
1.1K
论文数: 363
被引数: 9.3W
引用论文

引用论文

Antibody persistence after serogroup C meningococcal conjugate vaccine in children with sickle cell disease
err2016-08-01
err0
PREAI
errAlessandra R. Souza; Claudia M. Maruyama; Marco Aurélio P. Sáfadi; Marta H. Lopes; Raymundo S. Azevedo; Helen Findlow; Xilian Bai; Ray Borrow; Lily Y. Weckx
err分享
err收藏
Fluorescence spectra and geometry of 1,2-bis(9-acetoxy-10-anthryl)-ethane
err1994-01-01
err0
PREAI
errTsuneo Fujii; Hidenori Yamamoto; Kyoichi Oki; Satoshi Suzuki; Kiyoichi Hirakawa
err分享
err收藏
err分享
err收藏
Nitric oxide and interactions with reactive oxygen species in the development of melanoma, breast, and colon cancer: A redox signaling perspective
err2019-08-01
err62
errOAAI
errMonteiro, Hugo P.; Rodrigues, Elaine G.; Amorim Reis, Adriana K. C.; Longo, Luiz S., Jr.; Ogata, Fernando T.; Moretti, Ana I. S.; da Costa, Paulo E.; Teodoro, Ana C. S.; Toledo, Mayte S.; Stern, Arnold
err分享
err收藏
学者 查看更多内容