Generalized separable parameter space techniques for fitting 1K-5K serial compartment models

delete2013-06-24
delete14
delete
OA
AI
D
D.J. Kadrmas *
M
M. B. Oktay
DOI:10.1118/1.4810937delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Purpose: Kinetic modeling is widely used to analyze dynamic imaging data, estimating kinetic parameters that quantify functional or physiologic processes in vivo. Typical kinetic models give rise to nonlinear solution equations in multiple dimensions, presenting a complex fitting environment. This work generalizes previously described separable nonlinear least-squares techniques for fitting serial compartment models with up to three tissue compartments and five rate parameters. Methods: The approach maximally separates the linear and nonlinear aspects of the modeling equations, using a formulation modified from previous basis function methods to avoid a potential mathematical degeneracy. A fast and robust algorithm for solving the linear subproblem with full user-defined constraints is also presented. The generalized separable parameter space technique effectively reduces the dimensionality of the nonlinear fitting problem to one dimension for 2K-3K compartment models, and to two dimensions for 4K-5K models. Results: Exhaustive search fits, which guarantee identification of the true global minimum fit, required approximately 10 ms for 2K-3K and 1.1 s for 4K-5K models, respectively. The technique is also amenable to fast gradient-descent iterative fitting algorithms, where the reduced dimensionality offers improved convergence properties. The objective function for the separable parameter space nonlinear subproblem was characterized and found to be generally well-behaved with a well-defined global minimum. Separable parameter space fits with the Levenberg-Marquardt algorithm required fewer iterations than comparable fits for conventional model formulations, averaging 1 and 7 ms for 2K-3K and 4K-5K models, respectively. Sensitivity to initial conditions was likewise reduced. Conclusions: The separable parameter space techniques described herein generalize previously described techniques to encompass 1K-5K compartment models, enable robust solution of the linear subproblem with full user-defined constraints, and are amenable to rapid and robust fitting using iterative gradient-descent type algorithms. (C) 2013 Author(s). All article content, except where otherwise noted, is licensed under a Creative Commons Attribution 3.0 Unported License.
Keyword:
kinetic modeling
compartment modeling
dynamic imaging
positron emission tomography (PET)
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Medical Physics 封面图
Medical Physics
IF:
3.2
论文数:
3.7W
被引数:
3.2W

机构

U
Utah System of Higher Education
学者数:
4.6W
论文数: 4.0W
被引数: 161
引用论文

引用论文

Parametric mapping of [18F]fluoromisonidazole positron emission tomography using basis functions
err2010-08-25
err19
errOAAI
errHong, Young T.; Beech, John S.; Smith, Rob; Baron, Jean-Claude; Fryer, Tim D.
err分享
err收藏
Combining Field and Simulation Studies to Improve Fertilizer Recommendations for Irrigated Rice in Burkina Faso
err2005-09-01
err0
PREAI
errZ. Segda; S. M. Haefele; M. C. S. Wopereis; M. P. Sedogo; S. Guinko
err分享
err收藏
err分享
err收藏
Broadband synthetic aperture borehole radar interferometry
err2001-07-01
err0
PREAI
errI. Mason; N. Osman; Q. Liu; C. Simmat; M. Li
err分享
err收藏
学者 查看更多内容