arrow
返回

Generic method for automatic bladder segmentation on cone beam CT using a patient-specific bladder shape model

delete2014-02-19
delete17
PRE
AI
A
Agustinus J.A.J. van de Schoot *
G
G. Schooneveldt
S
Silvia Wognum
M
Mischa S. Hoogeman
X
Xiaodong Chai
L
Lukas J.A. Stalpers
C
C. Rasch
A
Arjan Bel
DOI:10.1118/1.4865762delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Purpose: The aim of this study is to develop and validate a generic method for automatic bladder segmentation on cone beam computed tomography (CBCT), independent of gender and treatment position (prone or supine), using only pretreatment imaging data. Methods: Data of 20 patients, treated for tumors in the pelvic region with the entire bladder visible on CT and CBCT, were divided into four equally sized groups based on gender and treatment position. The full and empty bladder contour, that can be acquired with pretreatment CT imaging, were used to generate a patient-specific bladder shape model. This model was used to guide the segmentation process on CBCT. To obtain the bladder segmentation, the reference bladder contour was deformed iteratively by maximizing the cross-correlation between directional grey value gradients over the reference and CBCT bladder edge. To overcome incorrect segmentations caused by CBCT image artifacts, automatic adaptations were implemented. Moreover, locally incorrect segmentations could be adapted manually. After each adapted segmentation, the bladder shape model was expanded and new shape patterns were calculated for following segmentations. All available CBCTs were used to validate the segmentation algorithm. The bladder segmentations were validated by comparison with the manual delineations and the segmentation performance was quantified using the Dice similarity coefficient (DSC), surface distance error (SDE) and SD of contour-to-contour distances. Also, bladder volumes obtained by manual delineations and segmentations were compared using a Bland-Altman error analysis. Results: The mean DSC, mean SDE, and mean SD of contour-to-contour distances between segmentations and manual delineations were 0.87, 0.27 cm and 0.22 cm (female, prone), 0.85, 0.28 cm and 0.22 cm (female, supine), 0.89, 0.21 cm and 0.17 cm (male, supine) and 0.88, 0.23 cm and 0.17 cm (male, prone), respectively. Manual local adaptations improved the segmentation results significantly (p < 0.01) based on DSC (6.72%) and SD of contour-to-contour distances (0.08 cm) and decreased the 95% confidence intervals of the bladder volume differences. Moreover, expanding the shape model improved the segmentation results significantly (p < 0.01) based on DSC and SD of contour-to-contour distances. Conclusions: This patient-specific shape model based automatic bladder segmentation method on CBCT is accurate and generic. Our segmentation method only needs two pretreatment imaging data sets as prior knowledge, is independent of patient gender and patient treatment position and has the possibility to manually adapt the segmentation locally. (C) 2014 American Association of Physicists in Medicine.
Keyword:
automatic bladder segmentation
adaptive radiation therapy
CBCT
image guidance
manual local adaptation
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Medical Physics 封面图
Medical Physics
IF:
3.2
论文数:
3.7W
被引数:
3.2W

机构

U
university of amsterdam
学者数:
6.0W
论文数: 5.1W
被引数: 94
A
academic medical center amsterdam
学者数:
1.5W
论文数: 1.3W
被引数: 17
E
Erasmus University Rotterdam
学者数:
4.6W
论文数: 4.0W
被引数: 2.4W
学者 查看更多机构
引用论文

引用论文

Comparing Two Tests for Two Rates
err2017-10-18
err0
PREAI
errChunpeng Fan; Lin Wang; Lynn Wei
err分享
err收藏
257 Are Stethoscopes and Infection Control Enemies?
err2020-10-01
err0
PREAI
errS. Kalra; J.B. Shewale; W.F. Peacock
err分享
err收藏
The Selective Closure of Civic Space
err2021-07-31
err0
errOAAI
errConny Roggeband; Andrea Krizsán
err分享
err收藏
Control over structure-specific flexibility improves anatomical accuracy for point-based deformable registration in bladder cancer radiotherapy
err2013-01-07
err22
PREAI
errWognum, S.; Bondar, L.; Zolnay, A. G.; Chai, X.; Hulshof, M. C. C. M.; Hoogeman, M. S.; Bel, A.
err分享
err收藏
err分享
err收藏
Conformal radiotherapy of urinary bladder cancer
err2004-12-01
err32
PREAI
errMuren, LP; Smaaland, R; Dahl, A
err分享
err收藏
Comparison of online IGRT techniques for prostate IMRT treatment: Adaptive vs repositioning correction
err2009-04-14
err61
PREAI
errThongphiew, Danthai; Wu, Q. Jackie; Lee, W. Robert; Chankong, Vira; Yoo, Sua; McMahon, Ryan; Yin, Fang-Fang
err分享
err收藏
Feasibility of CBCT-based target and normal structure delineation in prostate cancer radiotherapy: Multi-observer and image multi-modality study
err2011-02-01
err88
PREAI
errLuetgendorf-Caucig, Carola; Fotina, Irina; Stock, Markus; Poetter, Richard; Goldner, Gregor; Georg, Dietmar
err分享
err收藏
学者 查看更多内容