arrow
返回

Glucose biosensor based on open-source wireless microfluidic potentiostat

delete2019-07-01
delete34
delete
OA
AI
C
Conan Mercer *
R
Richard Bennett
P
Peter Ó Conghaile
J
James F. Rusling
D
Dónal Leech
DOI:10.1016/j.snb.2019.02.031delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Wireless potentiostats capable of cyclic voltammetry and amperometry that connect to the Internet are emerging as key attributes of future point-of-care devices. This work presents an integrated microfluidic electrochemical detector (iMED) three-electrode multi-potentiostat designed around operational amplifiers connected to a powerful WiFi-based microcontroller as a promising alternative to more expensive and complex strategies reported in the literature. The iMED is integrated with a microfluidic system developed to be controlled by the same microcontroller. The iMED is programmed wirelessly over a standard WiFi network and all electrochemical data is uploaded to an open-source cloud-based server. A wired desktop computer is not necessary for operation or program uploading. This method of integrated microfluidic automation is simple, uses common and inexpensive materials, and is compatible with commercial sample injectors. An integrated biosensor platform contains four screen-printed carbon arrays inside 4 separate microfluidic detection chambers with Pt counter and pseudo Ag/AgCl reference electrodes in situ. The iMED is benchmarked with K-3[Fe(CN)(6)] against a commercial potentiostat and then as a glucose biosensor using glucose-oxidising films of [Os(2,2'-bipyridine)(2)(polyvinylimidazole)(10)Cl] prepared on screen-printed electrodes with multi walled carbon nanotubes, poly(ethylene glycol) diglycidyl ether and flavin adenine dinucleotide-dependent glucose dehydrogenase. Potential application of this cost-effective wireless potentiostat approach to modern bioelectronics and point-of-care diagnosis is demonstrated by production of glucose oxidation currents, under pseudo-physiological conditions, using mediating films with lower redox potentials.
Keyword:
Wireless
Open-source
Enzyme-based biosensor
Microfluidic biosensor
Smartphone
IoT
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Sensors and Actuators B-Chemical 封面图
Sensors and Actuators B-Chemical
IF:
7.7
论文数:
3.4W
被引数:
12.6W

机构

D
Dublin City University
学者数:
5.6K
论文数: 5.0K
被引数: 5.2K
O
ollscoil na gaillimhe-university of galway
学者数:
1.1W
论文数: 8.7K
被引数: 5
引用论文

引用论文

err分享
err收藏
err分享
err收藏
err分享
err收藏
A miniature biofuel cell
err2001-08-11
err461
PREAI
errChen, T; Barton, SC; Binyamin, G; Gao, ZQ; Zhang, YC; Kim, HH; Heller, A
err分享
err收藏
Prevention of Thrombogenesis from Whole Human Blood on Plastic Polymer by Ultrathin Monoethylene Glycol Silane Adlayer
err2014-03-13
err44
PREAI
errFedorov, Kiril; Blaszykowski, Christophe; Sheikh, Sonia; Reheman, Adili; Romaschin, Alexander; Ni, Heyu; Thompson, Michael
err分享
err收藏
A fully automated immunoassay from whole blood on a disc
err2009-01-01
err319
PREAI
errLee, Beom Seok; Lee, Jung-Nam; Park, Jong-Myeon; Lee, Jeong-Gun; Kim, Suhyeon; Cho, Yoon-Kyoung; Ko, Christopher
err分享
err收藏
Screening reactive metabolites bioactivated by multiple enzyme pathways using a multiplexed microfluidic system
errANALYST
IF3.3
err2013-01-01
err17
errOAAI
errWasalathanthri, Dhanuka P.; Faria, Ronaldo C.; Malla, Spundana; Joshi, Amit A.; Schenkman, John B.; Rusling, James F.
err分享
err收藏
学者 查看更多内容