arrow
返回

GMR biosensor arrays: A system perspective

delete2010-05-01
delete156
delete
OA
AI
D
Drew A. Hall
R
Richard S. Gaster
T
Tai‐Yen Lin
S
Sebastian J. Osterfeld
S
Shu‐Jen Han
B
Boris Murmann
S
S.X. Wang *
DOI:10.1016/j.bios.2010.01.038delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Giant magnetoresistive biosensors are becoming more prevalent for sensitive, quantifiable biomolecular detection. However, in order for magnetic biosensing to become competitive with current optical protein microarray technology, there is a need to increase the number of sensors while maintaining the high sensitivity and fast readout time characteristic of smaller arrays (1-8 sensors). In this paper, we present a circuit architecture scalable for larger sensor arrays (64 individually addressable sensors) while maintaining a high readout rate (scanning the entire array in less than 4 s). The system utilizes both time domain multiplexing and frequency domain multiplexing in order to achieve this scan rate. For the implementation, we propose a new circuit architecture that does not use a classical Wheat-stone bridge to measure the small change in resistance of the sensor. Instead, an architecture designed around a transimpedance amplifier is employed. A detailed analysis of this architecture including the noise, distortion, and potential sources of errors is presented, followed by a global optimization strategy for the entire system comprising the magnetic tags, sensors, and interface electronics. To demonstrate the sensitivity, quantifiable detection of two blindly spiked samples of unknown concentrations has been performed at concentrations below the limit of detection for the enzyme-linked immunosorbent assay. Lastly, the multiplexing capability and reproducibility of the system was demonstrated by simultaneously monitoring sensors functionalized with three unique proteins at different concentrations in real-time. (C) 2010 Elsevier B.V. All rights reserved.
Keyword:
Magnetic biosensor
GMR biosensor
Spin-valve biosensor
Multiplexing spin-valves

期刊

Biosensors and Bioelectronics 封面图
Biosensors and Bioelectronics
IF:
10.5
论文数:
1.8W
被引数:
7.7W

机构

S
Stanford University
学者数:
9.6W
论文数: 8.2W
被引数: 17.0W
I
international business machines (ibm)
学者数:
5.7K
论文数: 4.5K
被引数: 4
引用论文

引用论文

An integrated and sensitive detection platform for magneto-resistive biosensors
err2007-04-01
err126
PREAI
errde Boer, B. M.; Kahlman, J. A. H. M.; Jansen, T. P. G. H.; Duric, H.; Veen, J.
err分享
err收藏
err
IF0
err
err0
PREAI
err
err分享
err收藏
Thin films of nanocrystalline graphene/graphite: An overview of synthesis and applications
err2020-03-02
err0
PREAI
errOctavian‐Gabriel Simionescu; Radu C. Popa; Andrei Avram; Gheorghe Dinescu
err分享
err收藏
The BARC biosensor applied to the detection of biological warfare agents
err2000-01-01
err450
PREAI
errEdelstein, RL; Tamanaha, CR; Sheehan, PE; Miller, MM; Baselt, DR; Whitman, LJ; Colton, RJ
err分享
err收藏
Femtomolar limit of detection with a magnetoresistive biochip磁阻生物芯片的飞摩尔检测限
err2009-04-01
err116
PREAI
errMartins, V. C.; Cardoso, F. A.; Germano, J.; Cardoso, S.; Sousa, L.; Piedade, M.; Freitas, P. P.; Fonseca, L. P.
err分享
err收藏
A biosensor based on magnetoresistance technology
err1998-10-01
err851
PREAI
errBaselt, DR; Lee, GU; Natesan, M; Metzger, SW; Sheehan, PE; Colton, RJ
err分享
err收藏
Giant Magenetoresistive Sensors. 2. Detection of Biorecognition Events at Self-Referencing and Magnetically Tagged Arrays
err2008-10-01
err46
PREAI
errMillen, Rachel L.; Nordling, John; Bullen, Heather A.; Porter, Marc D.; Tondra, Mark; Granger, Michael C.
err分享
err收藏
Giant magnetoresistive biochip for DNA detection and HPV genotyping用于DNA检测和HPV基因分型的巨磁阻生物芯片
err2008-09-01
err171
errOAAI
errXu, Liang; Yu, Heng; Akhras, Michael S.; Han, Shu-Jen; Osterfeld, Sebastian; White, Robert L.; Pourmand, Nader; Wang, Shan X.
err分享
err收藏
学者 查看更多内容