Fujimoto, Rintaro *
K
Kurihara, Tsuneya
N
Nagamine, Yoshihiko
DOI:10.1088/0031-9155/56/5/006delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Performance of a treatment planning system is an essential factor in making sophisticated plans. The dose calculation is a major time-consuming process in planning operations. The standard algorithm for proton dose calculations is the pencil beam algorithm which produces relatively accurate results, but is time consuming. In order to shorten the computational time, we have developed a GPU (graphics processing unit)-based pencil beam algorithm. We have implemented this algorithm and calculated dose distributions in the case of a water phantom. The results were compared to those obtained by a traditional method with respect to the computational time and discrepancy between the two methods. The new algorithm shows 5-20 times faster performance using the NVIDIA GeForce GTX 480 card in comparison with the Intel Core-i7 920 processor. The maximum discrepancy of the dose distribution is within 0.2%. Our results show that GPUs are effective for proton dose calculations.
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Physics in Medicine and Biology 封面图
Physics in Medicine and Biology
IF:
3.4
论文数:
1.4W
被引数:
3.1W

机构

H
hitachi limited
学者数:
2.2K
论文数: 1.5K
被引数: 0
引用论文

引用论文

The M. D. Anderson proton therapy systemThe M. D.安德森质子治疗系统
err2009-08-12
err178
PREAI
errSmith, Alfred; Gillin, Michael; Bues, Martin; Zhu, X. Ronald; Suzuki, Kazumichi; Mohan, Radhe; Woo, Shiao; Lee, Andrew; Komaki, Ritsko; Cox, James; Hiramoto, Kazuo; Akiyama, Hiroshi; Ishida, Takayuki; Sasaki, Toshie; Matsuda, Koji
err分享
err收藏
A convolution-superposition dose calculation engine for GPUs
err2010-02-08
err28
PREAI
errHissoiny, Sami; Ozell, Benoit; Despres, Philippe
err分享
err收藏
Dragon Bone Hill
err
IF0
err2004-04-22
err0
PREAI
errNoel T. Boaz; Russell L. Ciochon
err分享
err收藏
Implementation of pencil kernel and depth penetration algorithms for treatment planning of proton beams
err1999-12-01
err64
PREAI
errRussell, KR; Isacsson, U; Saxner, M; Ahnesjö, A; Montelius, A; Grusell, E; Dahlgren, CV; Lorin, S; Glimelius, B
err分享
err收藏
Development of a GPU-based Monte Carlo dose calculation code for coupled electron-photon transport
err2010-05-12
err134
errOAAI
errJia, Xun; Gu, Xuejun; Sempau, Josep; Choi, Dongju; Majumdar, Amitava; Jiang, Steve B.
err分享
err收藏
GPU-based ultra-fast dose calculation using a finite size pencil beam model
err2009-10-01
err96
errOAAI
errGu, Xuejun; Choi, Dongju; Men, Chunhua; Pan, Hubert; Majumdar, Amitava; Jiang, Steve B.
err分享
err收藏
Understanding Organizational Designs of Primary Care Practices
err2003-01-01
err0
PREAI
errAlfred F. Tallia; Kurt C. Stange; Reuben R. McDaniel; Virginia A. Aita; William L. Miller; Benjamin F. Crabtree
err分享
err收藏
Experimental characterization and physical modelling of the dose distribution of scanned proton pencil beams
err2005-01-20
err294
PREAI
errPedroni, E; Scheib, S; Böhringer, T; Coray, A; Grossmann, M; Lin, S; Lomax, A
err分享
err收藏
<title>Optical topography</title>
err1999-07-15
err0
PREAI
errAtsushi Maki; Yuichi Yamashita; Eiju Watanabe; Tsuyoshi Yamamoto; Kyuya Kogure; Fumio Kawaguchi; Hideaki Koizumi
err分享
err收藏
学者 查看更多内容