1
Return

Helical intensity-modulated radiation therapy vs. C-arm-based volumetric modulated arc therapy for sinonasal tumours: organ at risk sparing and treatment efficiency

delete2026-06-25
delete0
PRE
AI
S
Sandeep Singh *
S
Supratik Sen
D
Dipesh
A
Abhay Kumar Singh
M
Manindra Bhushan
S
Soniya Pal
A
Anuj Vijay
B
Benoy Kumar Singh
R
Raj Pal Singh
S
Sarthak Tandon
M
Munish Gairola
DOI:10.1007/s00066-026-02563-8delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
Sinonasal tumours present major radiotherapy challenges because of their proximity to the optic nerves, chiasm, and brainstem. This study aimed to evaluate helical intensity-modulated radiation therapy (HIMRT) and volumetric modulated arc therapy (VMAT), including coplanar and noncoplanar approaches, by integrating plan quality and treatment efficiency. A retrospective planning analysis of 467 patients with sinonasal tumours was conducted using HIMRT and VMAT planning techniques, whereby HIMRT with jaw widths of 1.0, 2.5, and 5.0 cm were compared with coplanar and noncoplanar VMAT plans. The planning evaluation included dose coverage (D95, D98, D2, D50%), homogeneity index, and dose spillage metrics (V10–V90%). Organ-at-risk doses were assessed for the optic apparatus, brainstem, and parotids. Efficiency was evaluated via monitor units and beam-on time, whereas delivery accuracy was validated via OSL dosimetry and gamma analysis. Both techniques achieved conformal dose coverage and OAR sparing. While HIMRT with narrow jaws improved conformity, it required substantially longer beam-on times. The VMAT plans provided comparable coverage and OAR protection with fewer hotspots, and they delivered treatment in less time. Noncoplanar VMAT offered only minor gains. Phantom validation confirmed the dose delivery accuracy, with OSLD deviations < 5% and gamma passes rates > 97%. While HIMRT and VMAT are both effective for sinonasal radiotherapy, VMAT offers superior efficiency with comparable plan quality. Therefore, HIMRT may be reserved for anatomically complex cases where marginal conformity benefits justify longer treatment times.
Keywords:
Helical intensity-modulated radiation therapy
Volumetric modulated arc therapy
Sinonasal neoplasms
C‑arm linear accelerator
Coplanar and noncoplanar delivery

Journal

Strahlentherapie und Onkologie cover
Strahlentherapie und Onkologie
IF:
2.5
Papers:
270
Citations:
3.4K

Organization

D
department of radiation oncology
Scholars:
826
Papers: 270
Citations: 0
D
department of physics
Scholars:
3.0K
Papers: 932
Citations: 0
Cited Papers

Cited Papers

Citing Papers

Citing Papers