arrow
返回

High-Energy X-ray Phase Tomography Using Grating Interferometer with Structured Anode X-ray Source

delete2021-09-09
delete3
PRE
AI
K
Kenji Kimura
M
Mengran Sun
R
Ryosuke Ueda
W
Wu, Yanlin
H
Haojie Pan
A
Atsushi Momose *
DOI:10.1117/12.2595488delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
For high-energy X-ray phase tomography, an inverse Talbot-Lau interferometer using a structured-anode X-ray source has been constructed. The structured anode has a tungsten line-and-space pattern whose period is 3 mu m. Thanks to the inverse geometry, a thick amplitude grating with a moderate aspect ratio is available for G2, resulting in a design energy of 82 keV. After confirming the operation of the source as expected, high-energy X-ray phase tomography was applied to a dry battery, which shows little transmission around 30 keV. Structural change in the negative electrode is depicted between tomograms reconstructed from scattering (dark-field) images of a fresh dry battery and identical fully-discharged one. From the viewpoint of practical application to non-destructive testing and medicine, exploring high-energy X-ray phase imaging is important. This result suggests that the use of the structured-anode X-ray source is effective for this purpose thus avoiding the challenge of developing extremely high-aspect-ratio gratings. If the period of the structured anode is reduced further, it will also be possible to remove G2.
Keyword:
grating
interferometry
phase tomography
structured-anode X-ray tube
non-destructive testing

期刊

暂无期刊信息

机构

T
tohoku university
学者数:
4.3W
论文数: 3.6W
被引数: 31