High-resolution extended source optical coherence tomography

delete2015-09-30
delete26
delete
OA
AI
X
Xiaojun Yu *
X
Xinyu Liu
S
Si Chen
Y
Yuemei Luo
王向红 封面图
王向红 (Xianghong Wang)
L
Linbo Liu
DOI:10.1364/OE.23.026399delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
High resolution optical coherence tomography (OCT) is capable of providing detailed tissue microstructures that are critical for disease diagnosis, yet its sensitivity is usually degraded since the system key components are typically not working at their respective center wavelengths. We developed a novel imaging system that achieves enhanced sensitivity without axial resolution degradation by the use of a spectrally encoded extended source (SEES) technique; it allows larger sample power without exceeding the maximum permissible exposure (MPE). In this study, we demonstrate a high-resolution extended source (HRES) OCT system, which is capable of providing a transverse resolution of 4.4 mu m and an axial resolution of 2.1 mu m in air with the SEES technique. We first theoretically show a sensitivity advantage of 6-dB of the HRES-OCT over that of its point source counterpart using numerical simulations, and then experimentally validate the applicability of the SEES technique to high-resolution OCT (HR-OCT) by comparing the HRES-OCT with an equivalent point-source system. In the HRES-OCT system, a dispersive prism was placed in the infinity space of the sample arm optics to spectrally extend the visual angle (angular subtense) of the light source to 10.3 mrad. This extended source allowed similar to 4 times larger MPE than its point source counterpart, which results in an enhancement of similar to 6 dB in sensitivity. Specifically, to solve the unbalanced dispersion between the sample and the reference arm optics, we proposed easy and efficient methods for system calibration and dispersion correction, respectively. With a maximum scanning speed reaching up to 60K A-lines/s, we further conducted imaging experiments with HRES-OCT using the human fingertip in vivo and the swine eye tissues ex vivo. Results demonstrate that the HRES-OCT is able to achieve significantly larger penetration depth than its conventional point source OCT counterpart. (C) 2015 Optical Society of America
Keyword:
ULTRAHIGH-RESOLUTION
HIGH-SPEED
HUMAN RETINA
OCT
LESIONS
BENIGN
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Optics Express 封面图
Optics Express
IF:
3.3
论文数:
6.1W
被引数:
14.3W

机构

N
Nanyang Technological University
学者数:
4.9W
论文数: 4.8W
被引数: 8.1W
引用论文

引用论文

Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation
err2004-05-31
err1.2K
errOAAI
errWojtkowski, M; Srinivasan, VJ; Ko, TH; Fujimoto, JG; Kowalczyk, A; Duker, JS
err分享
err收藏
Ultrahigh resolution Fourier domain optical coherence tomography
err2004-01-01
err523
errOAAI
errLeitgeb, RA; Drexler, W; Unterhuber, A; Hermann, B; Bajraszewski, T; Le, T; Stingl, A; Fercher, AF
err分享
err收藏
err分享
err收藏
High-speed spectral-domain optical coherence tomography at 1.3 μm wavelength
err2003-12-29
err579
errOAAI
errYun, SH; Tearney, GJ; Bouma, BE; Park, BH; de Boer, JF
err分享
err收藏
In vivo Fourier-domain full-field OCT of the human retina with 1.5 million A-lines/s
err2010-10-12
err129
PREAI
errBonin, Tim; Franke, Gesa; Hagen-Eggert, Martin; Koch, Peter; Huettmann, Gereon
err分享
err收藏
Automatic characterization and segmentation of human skin using three-dimensional optical coherence tomography
err2006-03-06
err89
errOAAI
errHori, Y; Yasuno, Y; Sakai, S; Matsumoto, M; Sugawara, T; Madjarova, VD; Yamanari, M; Makita, S; Araki, T; Itoh, M; Yatagai, T
err分享
err收藏
err分享
err收藏
State-of-the-art retinal optical coherence tomography
err2008-01-01
err712
PREAI
errDrexler, Wolfgang; Fujimoto, James G.
err分享
err收藏
学者 查看更多内容