arrow
返回

High-Resolution Time-Frequency Spectrum-Based Lung Function Test from a Smartphone Microphone

delete2016-08-17
delete23
delete
OA
AI
T
Tharoeun Thap
H
Heewon Chung
C
Chang‐Won Jeong
K
Ki‐Eun Hwang
H
Hak-Ryul Kim
K
Kwon‐Ha Yoon *
L
Lee, Jinseok *
DOI:10.3390/s16081305delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
In this paper, a smartphone-based lung function test, developed to estimate lung function parameters using a high-resolution time-frequency spectrum from a smartphone built-in microphone is presented. A method of estimation of the forced expiratory volume in 1 s divided by forced vital capacity (FEV1/FVC) based on the variable frequency complex demodulation method (VFCDM) is first proposed. We evaluated our proposed method on 26 subjects, including 13 healthy subjects and 13 chronic obstructive pulmonary disease (COPD) patients, by comparing with the parameters clinically obtained from pulmonary function tests (PFTs). For the healthy subjects, we found that an absolute error (AE) and a root mean squared error (RMSE) of the FEV1/FVC ratio were 4.49% +/- 3.38% and 5.54%, respectively. For the COPD patients, we found that AE and RMSE from COPD patients were 10.30% +/- 10.59% and 14.48%, respectively. For both groups, we compared the results using the continuous wavelet transform (CWT) and short-time Fourier transform (STFT), and found that VFCDM was superior to CWT and STFT. Further, to estimate other parameters, including forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), and peak expiratory flow (PEF), regression analysis was conducted to establish a linear transformation. However, the parameters FVC, FEV1, and PEF had correlation factor r values of 0.323, 0.275, and -0.257, respectively, while FEV1/FVC had an r value of 0.814. The results obtained suggest that only the FEV1/FVC ratio can be accurately estimated from a smartphone built-in microphone. The other parameters, including FVC, FEV1, and PEF, were subjective and dependent on the subject's familiarization with the test and performance of forced exhalation toward the microphone.
Keyword:
smartphone microphone
pulmonary function test
FEV1/FVC
COPD
high-resolution time-frequency
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Sensors 封面图
Sensors
IF:
3.5
论文数:
7.2W
被引数:
20.9W

机构

W
Wonkwang University
学者数:
3.2K
论文数: 2.9K
被引数: 2.2K
引用论文

引用论文

Using the lower limit of normal for the FEV1/FVC ratio reduces the misclassification of airway obstruction
errTHORAX
IF7.7
err2008-05-20
err433
errOAAI
errSwanney, M. P.; Ruppel, G.; Enright, P. L.; Pedersen, O. F.; Crapo, R. O.; Miller, M. R.; Jensen, R. L.; Falaschetti, E.; Schouten, J. P.; Hankinson, J. L.; Stocks, J.; Quanjer, P. H.
err分享
err收藏
Standardisation of spirometry肺活量测定的标准化
err2005-08-01
err1.4W
errOAAI
errMiller, MR; Hankinson, J; Brusasco, V; Burgos, F; Casaburi, R; Coates, A; Crapo, R; Enright, P; van der Grinten, CPM; Gustafsson, P; Jensen, R; Johnson, DC; MacIntyre, N; McKay, R; Navajas, D; Pedersen, OF; Pellegrino, R; Viegi, G; Wanger, J
err分享
err收藏
General considerations for lung function testing
err2005-07-01
err709
errOAAI
errMiller, MR; Crapo, R; Hankinson, J; Brusasco, V; Burgos, F; Casaburi, R; Coates, A; Enright, P; van der Grinten, CPM; Gustafsson, P; Jensen, R; Johnson, DC; MacIntyre, N; McKay, R; Navajas, D; Pedersen, OF; Pellegrino, R; Viegi, G; Wanger, J
err分享
err收藏
Surface Photochemistry of Adsorbed Nitrate: The Role of Adsorbed Water in the Formation of Reduced Nitrogen Species on α-Fe2O3 Particle Surfaces
err2013-12-20
err0
PREAI
errCharith E. Nanayakkara; Pradeep M. Jayaweera; Gayan Rubasinghege; Jonas Baltrusaitis; Vicki H. Grassian
err分享
err收藏
Spirometry Use Among Pediatric Primary Care Physicians
err2010-10-01
err75
PREAI
errDombkowski, Kevin J.; Hassan, Fauziya; Wasilevich, Elizabeth A.; Clark, Sarah J.
err分享
err收藏
err分享
err收藏
学者 查看更多内容