arrow
返回

High-throughput impedance spectroscopy biosensor array chip

delete2014-03-28
delete23
delete
OA
AI
X
Xiaowen Liu
L
Lin Li
A
Andrew J. Mason *
DOI:10.1098/rsta.2013.0107delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Impedance spectroscopy is a powerful tool for characterizing materials that exhibit a frequency dependent behaviour to an applied electric field. This paper introduces a fully integrated multi-channel impedance extraction circuit that can both generate AC stimulus signals over a broad frequency range and also measure and digitize the real and imaginary components of the impedance response. The circuit was fabricated in a 0.5 mu m complementary metal-oxide semiconductor. Tailored for cellular membrane interface characterization, the signal generator produces sinusoidal waves from 10 mHz to 10 kHz. To suit a variety of applications, the impedance extraction circuit provides a programmable current measurement range from 100 pA to 100 nA with a measured resolution of approximately 100 fA. Occupying only 0.045 mm(2) per measurement channel, the circuit is compact enough to include nearly 200 channels in a 3 x 3 mm(2) die area.
Keyword:
complementary metal-oxide semiconductor
impedance spectroscopy
biosensor array
frequency synthesizer
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

P
Philosophical Transactions of the Royal Society A-Mathematical Physical and Engineering Sciences
IF:
3.7
论文数:
7.7K
被引数:
2.8W

机构

M
michigan state university
学者数:
3.6W
论文数: 3.2W
被引数: 44
引用论文

引用论文

PROBLEMS OF DEFINING AND ASSESSING TEACHER EFFECTIVENESS
err2007-04-02
err0
PREAI
errWilliam Rabinowitz; Robert M. W. Travers
err分享
err收藏
Metodología para el mapeo de activos de salud en una comunidad
err2013-03-01
err0
errOAAI
errBlanca Botello; Sergio Palacio; Mercedes García; Mario Margolles; Federico Fernández; Mariano Hernán; Javier Nieto; Rafael Cofiño
err分享
err收藏
Computational Fluid Dynamics
err2012-01-01
err0
PREAI
errHoward H. Hu
err分享
err收藏
err分享
err收藏
Tethered lipid bilayer membranes: Formation and ionic reservoir characterization
err1998-01-14
err302
PREAI
errRaguse, B; Braach-Maksvytis, V; Cornell, BA; King, LG; Osman, PDJ; Pace, RJ; Wieczorek, L
err分享
err收藏
err分享
err收藏
A CMOS Electrochemical Impedance Spectroscopy (EIS) Biosensor Array
err2010-12-01
err242
PREAI
errManickam, Arun; Chevalier, Aaron; McDermott, Mark; Ellington, Andrew D.; Hassibi, Arjang
err分享
err收藏
Detection of heavy metal ions at femtomolar levels using protein-based biosensors
err1998-09-04
err182
PREAI
errBontidean, I; Berggren, C; Johansson, G; Csöregi, E; Mattiasson, B; Lloyd, JA; Jakeman, KJ; Brown, NL
err分享
err收藏
学者 查看更多内容