arrow
返回

High-throughput microfluidic device for single cell analysis using multiple integrated soft lithographic pumps

delete2016-03-17
delete18
PRE
AI
D
Damith E. W. Patabadige
T
Tom Mickleburgh
L
Lorin A. Ferris
G
Gage Brummer
A
Anne H. Culbertson
C
Christopher T. Culbertson *
DOI:10.1002/elps.201500557delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
The ability to accurately control fluid transport in microfluidic devices is key for developing high-throughput methods for single cell analysis. Making small, reproducible changes to flow rates, however, to optimize lysis and injection using pumps external to the microfluidic device are challenging and time-consuming. To improve the throughput and increase the number of cells analyzed, we have integrated previously reported micropumps into a microfluidic device that can increase the cell analysis rate to similar to 1000 cells/h and operate for over an hour continuously. In order to increase the flow rates sufficiently to handle cells at a higher throughput, three sets of pumps were multiplexed. These pumps are simple, low-cost, durable, easy to fabricate, and biocompatible. They provide precise control of the flow rate up to 9.2 nL/s. These devices were used to automatically transport, lyse, and electrophoretically separate T-Lymphocyte cells loaded with Oregon green and 6-carboxyfluorescein. Peak overlap statistics predicted the number of fully resolved single-cell electropherograms seen. In addition, there was no change in the average fluorescent dye peak areas indicating that the cells remained intact and the dyes did not leak out of the cells over the 1 h analysis time. The cell lysate peak area distribution followed that expected of an asynchronous steady-state population of immortalized cells.
Keyword:
Electrophoresis
Multilayer microfluidic devices
Peristaltic pumps
Single cell analysis
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Electrophoresis 封面图
Electrophoresis
IF:
2.5
论文数:
1.2W
被引数:
1.0W

机构

K
Kansas State University
学者数:
9.5K
论文数: 8.1K
被引数: 1.3W
引用论文

引用论文

The Trampoline and Serious Neurological Injuries
errJAMA
IF0
err1960-11-26
err0
PREAI
errWilliam G. Ellis
err分享
err收藏
Ameliorative action of eugenol on nitrate induced reproductive toxicity in male rats
err2024-12-01
err0
errOAAI
errSulanaikanahalli Vadyappa Rajini; Halugudde Nagaraja Sarjan; Shivabasavaiah
err分享
err收藏
err分享
err收藏
Microelectrophoresis platform for fast serial analysis of single cells
err2010-07-23
err33
errOAAI
errJiang, Dechen; Sims, Christopher E.; Allbritton, Nancy L.
err分享
err收藏
err分享
err收藏
err分享
err收藏
Microfluidic Cell Sorter (μFCS) for On-chip Capture and Analysis of Single Cells
err2012-05-02
err48
errOAAI
errChung, Jaehoon; Shao, Huilin; Reiner, Thomas; Issadore, David; Weissleder, Ralph; Lee, Hakho
err分享
err收藏
学者 查看更多内容