arrow
返回

Highly sensitive glucose biosensor based on CF4-plasma-modified interdigital transducer array (IDA) microelectrode

delete2010-08-01
delete4
PRE
AI
H
Hao-Min Huang
C
Chien‐Hung Liu
V
Vincent Lee
C
Chiapyng Lee *
M
Meng‐Jiy Wang
DOI:10.1016/j.snb.2010.06.030delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
A glucose biosensor with superior accuracy and sensitivity was successfully developed based on an interdigital transducer array (IDA) microelectrode. The IDA microelectrode was prepared by a photolithography procedure with sputter coated thin layers of both gold and SiO2, followed by tetrafluoromethane (CF4) plasma treatment. The enzymatic interactions between glucose and the reactants were monitored by cyclic voltammetry method to determine the blood glucose concentration. The surface properties of the developed glucose biosensor were characterized by electron spectroscopy for chemical analysis (ESCA), atomic force microscopy (AFM), and surface wettability. The correlations between the results of surface analyses and the current responses indicated that the CF4 plasma facilitated both the exposure of gold layer underneath the protection layer and the raise of surface hydrophobicity, and therefore the enhancement of the current responses. The developed IDA-microelectrode-based glucose biosensor showed particular precision and excellent reproducibility in measuring glucose concentration under the presence of common interferences and in real human blood measurements. Moreover, the IDA microelectrodes displayed a sensitivity of 0.13 mu A/(mg/dL) which is much higher than commercially available products. (C) 2010 Elsevier B.V. All rights reserved.
Keyword:
Interdigital transducer array (IDA) microelectrode
Glucose sensor
Tetrafluoromethane plasma
Surface characterizations
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Sensors and Actuators B-Chemical 封面图
Sensors and Actuators B-Chemical
IF:
7.7
论文数:
3.4W
被引数:
12.6W

机构

N
national taiwan university of science & technology
学者数:
8.8K
论文数: 8.7K
被引数: 9
引用论文

引用论文

Accuracy and utility of a 10-test disk blood glucose meter
err2005-01-01
err10
PREAI
errKendall, DM; Kaplan, RA; Paulson, CF; Parkes, JL; Tideman, AM
err分享
err收藏
Resilience Related to Quality of Life Perceived in Elderly Patients With Orthotopic Liver Transplant for More Than 10 Years
err2020-06-01
err0
PREAI
errMarta Jover-Aguilar; Laura Martínez-Alarcón; Guillermo Ramis; José Antonio Pons; Antonio Ríos; Beatriz Febrero; Felipe Alconchel-Gago; César Carrillo; Alberto Inocencio Hiciano Guillermo; Pascual Parrilla; Pablo Ramírez
err分享
err收藏
学者 查看更多内容