arrow
返回

Image integration using NavX fusion: Initial experience and validation

delete2008-04-01
delete55
PRE
AI
A
Anthony G. Brooks
L
Lauren Wilson
K
Kuklik, Pawet
M
Martin K. Stiles
B
Bobby John
D
Dennis H. Lau
R
Ross Roberts-Thomson
C
Christopher X. Wong
G
Glenn D. Young
P
Prashanthan Sanders *
DOI:10.1016/j.hrthm.2008.01.008delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
BACKGROUND Three-dimensional virtual anatomic navigation is increasingly used during mapping and ablation of complex atrhythmias. NavX Fusion software aims to mold the virtual anatomy to the patient's computed tomography (CT) image; however, the accuracy and clinical usefulness of this system have not been reported. OBJECTIVE The purpose of this study was to assess the accuracy and describe the initial experience of CT image integration using NavX Fusion for atrial fibrillation ablation. METHODS This study consisted of 55 consecutive patients undergoing atrial fibrillation ablation using NavX Fusion navigation. Left atrial NavX geometries were compared to a corresponding CT for geometric match. Geometric match, expressed as the difference in millimeters between CT and NavX geometry, was calculated for the original geometry (GEO-1), field scaled and primary fused geometry (GEO-2), and final secondary fused geometry (GEO-3). Navigational accuracy was assessed by moving the catheter to 10 discrete anatomic sites and determining the distance between the catheter tip and the closest GEO-2, GEO-3, and CT surface. Fusion integration time and procedural and fluoroscopic durations were recorded to assess clinical usefulness. RESULTS GEO-1, GEO-2 and GEO-3 were associated with CT-GEO errors of 6.6 +/- 2.8 mm, 4.1 +/- 0.7 mm, 1.9 +/- 0.4 mm, respectivety. Navigational accuracy was not significantly different for GEO-2 GEO-3, and CT at 3.4 +/- 1.6 mm to any surface. A significant p <= .001) inverse curvilinear relationship was present between case number and the time required for image integration (r(2) = 0.35) and the fluoroscopic time normalized for procedural duration (r(2) = 0.18). CONCLUSION Image integration using the NavX Fusion software is highly accurate and is associated with a progressive reduction in fluoroscopic time relative to procedural duration.
Keyword:
three-dimensional image integration
computed tomography
atrial fibrillation
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

Heart Rhythm 封面图
Heart Rhythm
IF:
5.7
论文数:
9.7K
被引数:
1.6W

机构

R
Royal Adelaide Hospital
学者数:
3.5K
论文数: 2.7K
被引数: 3.0K
引用论文

引用论文

Covariant N-string amplitude
err1987-01-01
err0
PREAI
errP. Di Vecchia; R. Nakayama; J.L. Petersen; J.R. Sidenius; S. Sciuto
err分享
err收藏
Integrated electroanatomic mapping with three-dimensional computed tomographic images for real-time guided ablations
err2006-01-17
err228
errOAAI
errDong, J; Calkins, H; Solomon, SB; Lai, SH; Dalal, D; Lardo, A; Brem, E; Preiss, A; Berger, RD; Halperin, H; Dickfeld, T
err分享
err收藏
Reduction of fluoroscopy exposure and procedure duration during ablation of atrial fibrillation using a novel anatomical navigation system
err2005-03-01
err114
errOAAI
errRotter, M; Takahashi, Y; Sanders, P; Haïssaguerre, M; Jaïs, P; Hsu, LF; Sacher, F; Pasquié, JL; Clementy, J; Hocini, M
err分享
err收藏
Pulmonary vein ostium geometry - Analysis by magnetic resonance angiography
err2003-01-07
err131
errOAAI
errWittkampf, FHM; Vonken, EJ; Derksen, R; Loh, P; Velthuis, B; Wever, EFD; Boersma, LVA; Rensing, BJ; Cramer, MJ
err分享
err收藏
Pulmonary vein anatomy in patients undergoing catheter ablation of atrial fibrillation - Lessons learned by use of magnetic resonance imaging
err2003-04-22
err379
errOAAI
errKato, R; Lickfett, L; Meininger, G; Dickfeld, T; Wu, R; Juang, G; Angkeow, P; LaCorte, J; Bluemke, D; Berger, R; Halperin, HR; Calkins, H
err分享
err收藏
Quantity and quality of muscle in patients recently diagnosed with colorectal cancer: a comparison with cancer-free controls
err2020-01-22
err0
PREAI
errMayra Cruz-Fernández; Alexander Achalandabaso-Ochoa; Tania Gallart-Aragón; Francisco Artacho-Cordón; María José Cabrerizo-Fernández; Nicolás Pacce-Bedetti; Irene Cantarero-Villanueva
err分享
err收藏
学者 查看更多内容