返回
Image integration using NavX fusion: Initial experience and validation
DOI:10.1016/j.hrthm.2008.01.008.png)
摘要
En 中文
BACKGROUND Three-dimensional virtual anatomic navigation is increasingly used during mapping and ablation of complex atrhythmias. NavX Fusion software aims to mold the virtual anatomy to the patient's computed tomography (CT) image; however, the accuracy and clinical usefulness of this system have not been reported. OBJECTIVE The purpose of this study was to assess the accuracy and describe the initial experience of CT image integration using NavX Fusion for atrial fibrillation ablation. METHODS This study consisted of 55 consecutive patients undergoing atrial fibrillation ablation using NavX Fusion navigation. Left atrial NavX geometries were compared to a corresponding CT for geometric match. Geometric match, expressed as the difference in millimeters between CT and NavX geometry, was calculated for the original geometry (GEO-1), field scaled and primary fused geometry (GEO-2), and final secondary fused geometry (GEO-3). Navigational accuracy was assessed by moving the catheter to 10 discrete anatomic sites and determining the distance between the catheter tip and the closest GEO-2, GEO-3, and CT surface. Fusion integration time and procedural and fluoroscopic durations were recorded to assess clinical usefulness. RESULTS GEO-1, GEO-2 and GEO-3 were associated with CT-GEO errors of 6.6 +/- 2.8 mm, 4.1 +/- 0.7 mm, 1.9 +/- 0.4 mm, respectivety. Navigational accuracy was not significantly different for GEO-2 GEO-3, and CT at 3.4 +/- 1.6 mm to any surface. A significant p <= .001) inverse curvilinear relationship was present between case number and the time required for image integration (r(2) = 0.35) and the fluoroscopic time normalized for procedural duration (r(2) = 0.18). CONCLUSION Image integration using the NavX Fusion software is highly accurate and is associated with a progressive reduction in fluoroscopic time relative to procedural duration.
Keyword:
three-dimensional image integration
computed tomography
atrial fibrillation
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
5.7
论文数:
9.7K
被引数:
1.6W
机构
引用论文
Integrated electroanatomic mapping with three-dimensional computed tomographic images for real-time guided ablations
CIRCULATION
IF38.6
Reduction of fluoroscopy exposure and procedure duration during ablation of atrial fibrillation using a novel anatomical navigation system
EUROPEAN HEART JOURNAL
IF35.6
Removal of Organophosphorus Pesticides from Aqueous Solution by Magnetic Fe3O4/Red Mud‐Nanoparticles
Pulmonary vein anatomy in patients undergoing catheter ablation of atrial fibrillation - Lessons learned by use of magnetic resonance imaging
CIRCULATION
IF38.6