返回
Image Quantification for TSPO PET with a Novel Image-Derived Input Function Method
DOI:10.3390/diagnostics12051161.png)
摘要
En 中文
There is a growing interest in using F-18-DPA-714 PET to study neuroinflammation and microglial activation through imaging the 18-kDa translocator protein (TSPO). Although quantification of F-18-DPA-714 binding can be achieved through kinetic modeling analysis with an arterial input function (AIF) measured with blood sampling procedures, the invasiveness of such procedures has been an obstacle for wide application. To address these challenges, we developed an image-derived input function (IDIF) that noninvasively estimates the arterial input function from the images acquired for F-18-DPA-714 quantification. Methods: The method entails three fully automatic steps to extract the IDIF, including a segmentation of voxels with highest likelihood of being the arterial blood over the carotid artery, a model-based matrix factorization to extract the arterial blood signal, and a scaling optimization procedure to scale the extracted arterial blood signal into the activity concentration unit. Two cohorts of human subjects were used to evaluate the extracted IDIF. In the first cohort of five subjects, arterial blood sampling was performed, and the calculated IDIF was validated against the measured AIF through the comparison of distribution volumes from AIF (V-T(,AIF)) and IDIF (V-T(,)IDIF). In the second cohort, PET studies from twenty-eight healthy controls without arterial blood sampling were used to compare V-T(,)IDIF with V-T(,)REF measured using a reference region-based analysis to evaluate whether it can distinguish high-affinity (HAB) and mixed-affinity (MAB) binders. Results: In the arterial blood-sampling cohort, VT derived from IDIF was found to be an accurate surrogate of the VT from AIF. The bias of V-T(,)IDIF was -5.8 +/- 7.8% when compared to V-T(,AIF), and the linear mixed effect model showed a high correlation between V-T(,AIF) and V-T(,)IDIF (p < 0.001). In the nonblood-sampling cohort, V-T(,)IDIF showed a significance difference between the HAB and MAB healthy controls. V-T(,)IDIF and standard uptake values (SUV) showed superior results in distinguishing HAB from MAB subjects than V-T(,)REF. Conclusions: A novel IDIF method for F-18-DPA-714 PET quantification was developed and evaluated in this study. This IDIF provides a noninvasive alternative measurement of V-T to quantify the TSPO binding of F-18-DPA-714 in the human brain through dynamic PET scans.
Keyword:
TSPO PET
neuroinflammation
image-derived input function
kinetic modeling analysis
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
3.3
论文数:
2.0W
被引数:
3.6W
机构
引用论文
A comparative study of lithium ion (LFP) to lead acid (VRLA) battery for use in telecom power system


