Imaging Performance for Two Row-Column Arrays

delete2019-07-01
delete34
delete
OA
AI
H
Hamed Bouzari
M
Mathias Engholm
S
Svetoslav Ivanov Nikolov
M
Matthias Bo Stuart
E
Erik Vilain Thomsen
J
Jørgen Arendt Jensen *
DOI:10.1109/TUFFC.2019.2914348delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
This study evaluates the volumetric imaging performance of two prototyped 62 + 62 row-column-addressed (RCA) 2-D array transducer probes using three synthetic aperture imaging (SAI) emission sequences and two different beamformers. The probes are fabricated using capacitive micromachined ultrasonic transducer (CMUT) and piezoelectric transducer (PZT) technology. Both have integrated apodization to reduce ghost echoes and are designed with similar acoustical features, i.e., 3-MHz center frequency, lambda/2 pitch, and 24.8 x 24.8 mm(2) active footprint. Raw RF data are obtained using an experimental research ultrasound scanner, SARUS. The SAI sequences are designed for imaging down to 14 cm at a volume rate of 88 Hz. Two beamforming methods, spatial matched filtering and row-column adapted delay-and-sum, are used for beamforming the RF data. The imaging quality is investigated through simulations and phantom measurements. Both probes on average have similar lateral full-width at half-maximum (FWHM) values, but the PZT probe has 20% smaller cystic resolution values and 70% larger contrast-to-noise ratio (CNR) compared to the capacitive micromachined ultrasonic transducer (CMUT) probe. The CMUT probe can penetrate down to 15 cm, and the PZT probe down to 30 cm. The CMUT probe has 17% smaller axial FWHM values. The matched filter focusing shows an improved B-mode image for measurements on a cyst phantom with an improved speckle pattern and better visualization of deeper lying cysts. The results of this study demonstrate the potentials of RCA 2-D arrays against fully addressed 2-D arrays, which are low channel count (e.g., 124 instead of 3844), low acoustic intensity mechanical index (MI <= 0.88 and spatial-peak-temporal-average intensity I-spta <= 5.5 mW/cm(2)), and high penetration depth (down to 30 cm), which makes 3-D imaging at high volume rates possible with equipment in the price range of conventional 2-D imaging.
Keyword:
3-D imaging
beamforming
row-column arrays
volumetric ultrasound imaging
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control 封面图
IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control
IF:
3.7
论文数:
6.7K
被引数:
1.4W

机构

T
technical university of denmark
学者数:
2.6W
论文数: 2.8W
被引数: 37
引用论文

引用论文

A One-Sided Wall
err2004-07-01
err0
errOAAI
errWendy Pullan
err分享
err收藏
Effect of Different Prehydrolysis Processes on Lignin Extractability of Coconut Husk Fibres
err2019-12-25
err0
errOAAI
errBryan Carre; Marc Hebrant; Nicolas Brosse; Nur Hanis Abd. Latif; Mohd Hazwan Hussin
err分享
err收藏
err分享
err收藏
Probe development of CMUT and PZT row-column-addressed 2-D arrays
err2018-04-01
err28
errOAAI
errEngholm, Mathias; Bouzari, Hamed; Christiansen, Thomas Lehrmann; Beers, Christopher; Bagge, Jan Peter; Moesner, Lars Nordahl; Diederichsen, Soren Elmin; Stuart, Matthias Bo; Jensen, Jorgen Arendt; Thomsen, Erik Vilain
err分享
err收藏
Curvilinear 3-D Imaging Using Row-Column-Addressed 2-D Arrays With a Diverging Lens: Feasibility Study
err2017-06-01
err26
errOAAI
errBouzari, Hamed; Engholm, Mathias; Beers, Christopher; Stuart, Matthias Bo; Nikolov, Svetoslav Ivanov; Thomsen, Erik Vilain; Jensen, Jorgen Arendt
err分享
err收藏
err分享
err收藏
学者 查看更多内容