1
Return

Impact of device implantation depth on blood flow dynamics after left atrial appendage closure

delete2026-04-01
delete0
PRE
AI
C
Cepas-Guillen, Pedro
A
Albors, Carlos
M
Mill, Jordi
A
Aminian, Adel
G
Garot, Philippe
D
De Backer, Ole
N
Nielsen-Kudsk, Jens Erik
I
Iriart, Xavier
B
Barreiro-Perez, Manuel
F
Flores-Umanzor, Eduardo
C
Cruz-Gonzalez, Ignacio
A
Arzamendi, Dabit
A
Avvedimento, Marisa
N
Nombela-Franco, Luis
L
Leduc, Nina
H
Horvilleur, Jerome
K
Kofoed, Klaus Fuglsang
K
Korsholm, Kasper
C
Cochet, Hubert
E
Estevez-Loureiro, Rodrigo
B
Barrouhou, Manal
L
Lafond, Ana
M
Millan, Xavi
L
Laura Sanchís
R
Rodes-Cabau, Josep
C
Camara, Oscar
F
Freixa, Xavier *
DOI:10.4244/EIJ-D-25-01328delete
deleteOriginal
deleteOriginal request for help
deleteShare
deleteSave
Abstract

Abstract

En 中文
BACKGROUND: Device-related thrombus (DRT) remains a concern after left atrial appendage closure (LAAC), particularly when the device is deeply implanted. However, the mechanistic links between implantation depth, flow dynamics, and DRT risk are not well understood. AIMS: We therefore aimed to evaluate the impact of LAAC device implantation depth on local flow characteristics and its association with DRT using patient-specific computational fluid dynamics (CFD). METHODS: The study included 285 patients undergoing LAAC with either Amplatzer Amulet or WATCHMAN devices at 10 centres. Patient-specific CFD simulations were performed using postprocedural computed tomography and echocardiography-derived boundary conditions to assess blood flow dynamics. The primary endpoint was the comparison of CFD-derived flow indices-device surface velocity index (DSVI), endothelial cell activation potential (ECAP), and the presence of eddies/stagnated flow-between proximal and distal device implantation groups. Secondary analyses explored the relationship between these flow features and DRT. RESULTS: Proximal implants (57.2%) showed more favourable flow patterns: higher DSVI (0.11 m/s vs 0.09 m/s; p=0.002), lower ECAP (0.75 vs 0.90; p=0.003), and fewer recirculating zones (40.5% vs 74.6%; p<0.001). DRT incidence increased with greater implantation depth, paralleled by worsening flow indices. A composite CFD-based DRT risk score, incorporating ECAP, implantation depth, and flow complexity, demonstrated good discrimination (area under the receiver operating characteristic curve [AUC] 0.81), outperforming anatomical depth alone (AUC 0.71). CONCLUSIONS: Deeper LAAC device implantation is associated with adverse flow profiles and a higher risk of DRT. CFD-based flow characterisation may enhance risk stratification beyond anatomical criteria alone. Further studies incorporating clinical variables are warranted to validate these methods.
Keywords:
atrial fibrillation
computational fluid dynamics
device-related thrombus
left atrial appendage closure

Journal

E
EuroIntervention
IF:
9.5
Papers:
4.2K
Citations:
7.8K

Organization

J
jacques cartier private hospital
Scholars:
400
Papers: 312
Citations: 0
P
pompeu fabra university
Scholars:
423
Papers: 275
Citations: 4
C
CHU Bordeaux
Scholars:
8.4K
Papers: 6.4K
Citations: 51
A
aarhus university
Scholars:
3.7K
Papers: 1.6K
Citations: 0
U
university of barcelona
Scholars:
6.0W
Papers: 4.5W
Citations: 74
U
Université de Bordeaux
Scholars:
505
Papers: 255
Citations: 2.5W
Hospital Clínic de Barcelona cover
Hospital Clínic de Barcelona
Scholars:
707
Papers: 257
Citations: 1.1W
U
university of copenhagen
Scholars:
6.3K
Papers: 2.5K
Citations: 0
U
Universite Paris Saclay
Scholars:
7.2W
Papers: 5.2W
Citations: 540
I
idibaps
Scholars:
7.8K
Papers: 5.8K
Citations: 25
Cited Papers

Cited Papers

Citing Papers

Citing Papers