arrow
返回

Improved Cochlear Implant Performance Estimation Using Tonotopic-Based Electrocochleography

delete2023-12-01
delete9
PRE
AI
A
Amit Walia *
M
Matthew Shew
J
Jordan Varghese
P
Patrick Ioerger
S
Shannon M. Lefler
A
Amanda J. Ortmann
J
Jacques A. Herzog
C
Craig A. Buchman
DOI:10.1001/jamaoto.2023.2988delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Importance Cochlear implantation produces remarkable results in postlingual deafness, although auditory outcomes vary. Electrocochleography (ECochG) has emerged as a valuable tool for assessing the cochlear-neural substrate and evaluating patient prognosis.Objective To assess whether ECochG-total response (ECochG-TR) recorded at the best-frequency electrode (BF-ECochG-TR) correlates more strongly with speech perception performance than ECochG-TR measured at the round window (RW-ECochG-TR).Design, Setting, and Participants This single-center cross-sectional study recruited 142 patients from July 1, 2021, to April 30, 2022, with 1-year follow-up. Exclusions included perilymph suctioning, crimped sound delivery tubes, non-native English speakers, inner ear malformations, nonpatent external auditory canals, or cochlear implantation revision surgery.Exposures Cochlear implantation.Main Outcomes and Measures Speech perception testing, including the consonant-nucleus-consonant (CNC) words test, AzBio sentences in quiet, and AzBio sentences in noise plus 10-dB signal to noise ratio (with low scores indicating poor performance and high scores indicating excellent performance on all tests), at 6 months postoperatively; and RW-ECochG-TR and BF-ECochG-TR (measured for 250, 500, 1000, and 2000 Hz).Results A total of 109 of the 142 eligible postlingual adults (mean [SD] age, 68.7 [15.8] years; 67 [61.5%] male) were included in the study. Both BF-ECochG-TR and RW-ECochG-TR were correlated with 6-month CNC scores (BF-ECochG-TR: r = 0.74; 95% CI, 0.62-0.82; RW-ECochG-TR: r = 0.67; 95% CI, 0.54-0.76). A multivariate model incorporating age, duration of hearing loss, and angular insertion depth did not outperform BF-ECochG-TR or RW-ECochG-TR alone. The BF-ECochG-TR correlation with CNC scores was significantly stronger than the RW-ECochG-TR correlation (r difference = -0.18; 95% CI, -0.31 to -0.01; z = -2.02). More moderate correlations existed between 6-month AzBio scores in noise, Montreal Cognitive Assessment (MoCA) scores (r = 0.46; 95% CI, 0.29-0.60), and BF-ECochG-TR (r = 0.42; 95% CI, 0.22-0.58). MoCA and the interaction between BF-ECochG-TR and MoCA accounted for a substantial proportion of variability in AzBio scores in noise at 6 months (R2 = 0.50; 95% CI, 0.36-0.61).Conclusions and Relevance In this case series, BF-ECochG-TR was identified as having a stronger correlation with cochlear implantation performance than RW-ECochG-TR, although both measures highlight the critical role of the cochlear-neural substrate on outcomes. Demographic, audiologic, and surgical factors demonstrated weak correlations with cochlear implantation performance, and performance in noise was found to require a robust cochlear-neural substrate (BF-ECochG-TR) as well as sufficient cognitive capacity (MoCA). Future cochlear implantation studies should consider these variables when assessing performance and related interventions.
Keyword:
ROUND WINDOW ELECTROCOCHLEOGRAPHY
SPEECH RECOGNITION
OUTCOMES
RECORDINGS
POSITION

期刊

J
JAMA Otolaryngology-Head and Neck Surgery
IF:
5.6
论文数:
3.6K
被引数:
7.0K

机构

W
washington university (wustl)
学者数:
5.5W
论文数: 4.5W
被引数: 70
引用论文

引用论文

Immunoreactive analogues of erythrocyte ankyrin in human epidermal keratinocytes
err1996-01-01
err0
PREAI
errTadamichi Shimizu; Yuichi Takakuwa; Hiroko Koizumi; Teruo Ishibashi; Akira Ohkawara
err分享
err收藏
Association of Patient-Related Factors With Adult Cochlear Implant Speech Recognition Outcomes A Meta-analysis
err2020-07-01
err65
errOAAI
errZhao, Elise E.; Dornhoffer, James R.; Loftus, Catherine; Nguyen, Shaun A.; Meyer, Ted A.; Dubno, Judy R.; McRackan, Theodore R.
err分享
err收藏
Electrocochleography and cognition are important predictors of speech perception outcomes in noise for cochlear implant recipients
err2022-02-23
err34
errOAAI
errWalia, Amit; Shew, Matthew A.; Kallogjeri, Dorina; Wick, Cameron C.; Durakovic, Nedim; Lefler, Shannon M.; Ortmann, Amanda J.; Herzog, Jacques A.; Buchman, Craig A.
err分享
err收藏
Assessment of Speech Understanding After Cochlear Implantation in Adult Hearing Aid Users: A Nonrandomized Controlled Trial
err2020-10-01
err35
errOAAI
errBuchman, Craig A.; Herzog, Jacques A.; McJunkin, Jonathan L.; Wick, Cameron C.; Durakovic, Nedim; Firszt, Jill B.; Kallogjeri, Dorina
err分享
err收藏
Development and Validation of the AzBio Sentence Lists
err2012-01-01
err503
errOAAI
errSpahr, Anthony J.; Dorman, Michael F.; Litvak, Leonid M.; Van Wie, Susan; Gifford, Rene H.; Loizou, Philipos C.; Loiselle, Louise M.; Oakes, Tyler; Cook, Sarah
err分享
err收藏
Intra-and Postoperative Electrocochleography May Be Predictive of Final Electrode Position and Postoperative Hearing Preservation
err2017-05-29
err80
errOAAI
errO'Connell, Brendan P.; Holder, Jourdan T.; Dwyer, Robert T.; Gifford, Rene H.; Noble, Jack H.; Bennett, Marc L.; Rivas, Alejandro; Wanna, George B.; Haynes, David S.; Labadie, Robert F.
err分享
err收藏
err分享
err收藏
学者 查看更多内容