arrow
返回

Improved high operating temperature MCT MWIR modules

delete2014-06-24
delete16
PRE
AI
H
H. Lutz *
R
Rainer Breiter
H
Heinrich Figgemeier
T
T. Schallenberg
W
W. Schirmacher
R
R. Wollrab
DOI:10.1117/12.2050427delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
High operating temperature (HOT) IR-detectors are a key factor to size, weight and power (SWaP) reduced IR-systems. Such systems are essential to provide infantrymen with low-weight handheld systems with increased battery lifetimes or most compact clip-on weapon sights in combination with high electro-optical performance offered by cooled IR-technology. AIM's MCT standard n-on-p technology with vacancy doping has been optimized over many years resulting in MWIR-detectors with excellent electro-optical performance up to operating temperatures of similar to 120K. In the last years the effort has been intensified to improve this standard technology by introducing extrinsic doping with Gold as an acceptor. As a consequence the dark current could considerably be suppressed and allows for operation at similar to 140K with good e/o performance. More detailed investigations showed that limitation for HOT > 140K is explained by consequences from rising dark current rather than from defective pixel level. Recently, several crucial parameters were identified showing great promise for further optimization of HOT-performance. Among those, p-type concentration could successfully be reduced from the mid 1016/cm(3) to the lower 1015/cm(3) range. Since AIM is one of the leading manufacturers of split linear cryocoolers, an increase in operating temperature will directly lead to IR-modules with improved SWaP characteristics by making use of the miniature members of its SX cooler family with single piston and balancer technology. The paper will present recent progress in the development of HOT MWIR-detector arrays at AIM and show electro-optical performance data in comparison to focal plane arrays produced in the standard technology.
Keyword:
MCT
IR-module
SWaP
high operating temperature
dark current
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

I
Infrared Technology and Applications
IF:
0
论文数:
23
被引数:
0

机构

R
rheinmetall ag
学者数:
23
论文数: 11
被引数: 0
引用论文

引用论文

Usefulness of follicular dendritic cell pattern in classification of peripheral T‐cell lymphomas
err2007-04-03
err0
PREAI
errC. Y. LEUNG; F. C. S. HO; G. SRIVASTAVA; S. L. LOKE; Y. T. LIU; A. C. L. CHAN
err分享
err收藏
Role of cytokines in distribution and differentiation of dendritic cell/langerhans' cell lineage in human primary carcinomas of the lung
err1995-08-01
err0
PREAI
errAntonella Colasante; Graziella Castrilli; Francesca Bianca Aiello; Mauro Brunetti; Piero Musiani
err分享
err收藏
Langerhans' cell histiocytosis (histiocytosis X): Immunophenotype and growth fraction
err1993-08-01
err0
PREAI
errChristine Hage; Cheryl L. Willman; Blaise E. Favara; Peter G. Isaacson
err分享
err收藏
Human Herpesvirus 6 Is Present in Lesions of Langerhans Cell Histiocytosis
err1993-11-01
err0
PREAI
errMaureen A Leahy; Sonja M Krejci; Marti Friednash; Stephen S Stockert; Harry Wilson; J Clark Huff; William L Weston; Sylvia L Brice
err分享
err收藏
没有更多内容