arrow
返回

Improved machine tool linear axis calibration through continuous motion data capture

delete2017-01-01
delete14
delete
OA
AI
J
Judith E. Miller *
A
Andrew P. Longstaff
S
Simon Parkinson
S
Simon Fletcher
DOI:10.1016/j.precisioneng.2016.08.010delete
delete原文链接
delete分享
delete收藏
查看原文
摘要

摘要

En 中文
Machine tool calibration is becoming recognised as an important part of the manufacturing process. The current international standards for machine tool linear axes calibration support the use of quasi-static calibration techniques. These techniques can be time consuming but more importantly a compromise in quality due to the practical restriction on the spatial resolution of target positions on the axis under test. Continuous motion calibration techniques have the potential to dramatically increase calibration quality. Through taking several measurement values per second while the axis under test is in motion, it is possible to measure in far greater detail. Furthermore, since machine tools normally operate in dynamic mode, the calibration data can be more representative if it is captured while the machine is in motion. The drawback to measuring the axis while in motion is the potential increase in measurement uncertainty. In the following paper, different methods of continuous motion calibration are discussed. A time-based continuous motion solution is proposed as well as a novel optimisation and correlation algorithm to accurately fuse the data taken from quasi-static and continuous motion measurements. The measurement method allows for minimal quasi-static measurements to be taken while using a continuous motion measurement to enhance the calibration process with virtually no additional time constraints. The proposed method does not require any additional machine interfacing, making it a more readily accessible solution for widespread machine tool use than other techniques which require hardware links to the CNC. The result of which means a shorter calibration routine and enhanced results. The quasi-static and continuous motion measurements showed correlation to within 1 pm at the quasi-static measurement targets. An error of 13 mu m was detailed on the continuous motion, but was missed using the standard test. On a larger, less accurate machine, the quasi-static and continuous motion measurements were on average within 3 mu m of each other however, showed a standard deviation of 4 mu m which is less than 1% of the overall error. Finally, a high frequency cyclic error was detected in the continuous motion measurement but was missed in the quasi-static measurement. (C) 2016 The Author(s). Published by Elsevier Inc.
Keyword:
Machine tool calibration
Continuous motion measurement
Quasi-static measurement
Geometric error
Manufacturing
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

P
Precision Engineering-Journal of the International Societies for Precision Engineering and Nanotechnology
IF:
3.7
论文数:
3.3K
被引数:
8.3K

机构

U
University of Huddersfield
学者数:
3.0K
论文数: 3.2K
被引数: 3.6K
引用论文

引用论文

Recyclable Bi2WO6-nanoparticle mediated one-pot multicomponent reactions in aqueous medium at room temperature
err2014-01-01
err0
PREAI
errBanoth Paplal; S. Nagaraju; Palakollu Veerabhadraiah; Kodam Sujatha; Sriram Kanvah; B. Vijaya Kumar; Dhurke Kashinath
err分享
err收藏
Ultrasound-based approach to spiro-2,3-dihydroquinazolin-4(1H)-ones: their in vitro evaluation against chorismate mutase
err2013-02-01
err0
PREAI
errD. Rambabu; S. Kiran Kumar; B. Yogi Sreenivas; Sandhya Sandra; Ajit Kandale; Parimal Misra; M.V. Basaveswara Rao; Manojit Pal
err分享
err收藏
Nitrogen
err2005-05-13
err0
PREAI
errThomas L. Hardenburger; Matthew Ennis
err分享
err收藏
Cu−NHC Complex for Chan‐Evans‐Lam Cross‐Coupling Reactions of N‐Heterocyclic Compounds and Arylboronic Acids
err2023-09-22
err0
PREAI
errBhupendra Adhikari; Mohsen Teimouri; James W. Akin; Selvam Raju; Sean L. Stokes; Joseph P. Emerson
err分享
err收藏
err分享
err收藏
Geometric error measurement and compensation of machines-An update
err2008-01-01
err754
PREAI
errSchwenke, H.; Knapp, W.; Haitjema, H.; Weckenmann, A.; Schmitt, R.; Delbressine, F.
err分享
err收藏
学者 查看更多内容