1
Return

Improved postprandial glucose control with ultra rapid lispro versus lispro with continuous subcutaneous insulin infusion in type 1 diabetes: PRONTO-Pump-2

delete2021-03-23
delete28
delete
OA
AI
M
Mark Warren
B
Bruce W. Bode
J
Jang Ik Cho
R
Rong Liu
J
Janet Tobian
T
Thomas A. Hardy
F
Farai Chigutsa
M
Moshe Phillip
B
Barry Horowitz
D
Debra A. Ignaut *
DOI:10.1111/dom.14368delete
deleteOriginal
deleteShare
deleteSave
View PDF
Abstract

Abstract

En 中文
Aim To evaluate the efficacy and safety of ultra rapid lispro (URLi) versus lispro (Humalog(R)) in people with type 1 diabetes on continuous subcutaneous insulin infusion (CSII). Materials and Methods This was a phase 3, 16-week, treat-to-target study in patients randomized to double-blind URLi (N = 215) or lispro (N = 217). The primary endpoint was change from baseline HbA1c (non-inferiority margin 4.4 mmol/mol [0.4%]), with multiplicity-adjusted objectives for postprandial glucose (PPG) levels during a meal test, and time spent in the target range 70-180 mg/dL (TIR). Results URLi was non-inferior to lispro for change in HbA1c, with a least-squares mean (LSM) difference of 0.3 mmol/mol (95% confidence interval [CI] -0.6, 1.2) or 0.02% (95% CI -0.06, 0.11). URLi was superior to lispro in controlling 1- and 2-h PPG levels after the meal test: LSM difference -1.34 mmol/L (95% CI -2.00, -0.68) or -24.1 mg/dL (95% CI -36.0, -12.2) at 1 h and -1.54 mmol/L (95% CI -2.37, -0.72) or -27.8 mg/dL (95% CI -42.6, -13.0) at 2 h; both p < .001. TIR and time in hyperglycaemia were similar between groups but URLi resulted in significantly less time in hypoglycaemia (<3.0 mmol/L [54 mg/dL]) over the daytime, night-time and 24-h period: LSM difference -0.41%, -0.97% and -0.52%, respectively, all p < .05. The incidence of treatment-emergent adverse events was higher with URLi (60.5% vs. 44.7%), driven by infusion-site reaction and infusion-site pain, which was mostly mild or moderate. Rates of severe hypoglycaemia and diabetic ketoacidosis were similar between groups. Conclusions URLi was efficacious, providing superior PPG control and less time in hypoglycaemia but with more frequent infusion-site reactions compared with lispro when administered by CSII.
Keywords:
continuous glucose monitoring
continuous subcutaneous insulin infusion
insulin analogues
type 1 diabetes
AI Summary

AI Summary

Key information extracted from the uploaded paper, including a brief overview, abstract, background, key highlights, visual analysis, and future outlook.

Journal

D
Diabetes Obesity and Metabolism
IF:
5.7
Papers:
6.1K
Citations:
1.7W

Organization

S
Sackler Faculty of Medicine
Scholars:
8.7K
Papers: 6.6K
Citations: 4
E
Eli Lilly
Scholars:
1.0W
Papers: 5.9K
Citations: 10
L
lilly research laboratories
Scholars:
1.5K
Papers: 865
Citations: 1
T
Tel Aviv University
Scholars:
3.7W
Papers: 3.0W
Citations: 3.6W
Cited Papers

Cited Papers

Citing Papers

Citing Papers