Improving GRAPPA Using Cross-Sampled Autocalibration Data
DOI:10.1002/mrm.23083.png)
摘要
En 中文
In conventional generalized autocalibrating partially parallel acquisitions, the autocalibration signal (ACS) lines are acquired with a frequency-encoding direction in parallel to other undersampled lines. In this study, a cross sampling method is proposed to acquire the ACS lines orthogonal to the undersampled lines. This cross sampling method increases the amount of calibration data along the direction, where k-space is undersampled, and especially improves the calibration accuracy when a small number of ACS lines are acquired. The cross sampling method is implemented with swapped frequency and phase encoding gradients. In addition, an iterative coregistration method is also developed to correct the inconsistency between the ACS and undersampled data, which are acquired separately in two orthogonal directions. The same calibration and reconstruction procedure as conventional generalized autocalibrating partially parallel acquisitions is then applied to the corrected data to recover the unacquired k-space data and obtain the final image. Reconstruction results from simulations, phantom and in vivo human brain experiments have distinctly demonstrated that the proposed method, named cross-sampled generalized autocalibrating partially parallel acquisitions, can effectively reduce the aliasing artifacts of conventional generalized autocalibrating partially parallel acquisitions when very few ACS lines are acquired, especially at high outer k-space reduction factors. Magn Reson Med 67:1042-1053, 2012. (c) 2011 Wiley Periodicals, Inc.
Keyword:
GRAPPA
autocalibration
ACS
cross sampling
k-space registration
AI总结
对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。
期刊
IF:
3
论文数:
1.2W
被引数:
3.1W
机构
引用论文
The Effect of Reconstruction and Acquisition Parameters for GRAPPA-Based Parallel Imaging on the Image Quality基于GRAPPA的并行成像重建和采集参数对图像质量的影响
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays同时采集空间谐波 (SMASH): 使用射频线圈阵列进行快速成像
Chemical-shift artifact reduction in hadamard-encoded MR spectroscopic imaging at high (3T and 7T) magnetic fields在高 (3T和7T) 磁场下hadamard编码的MR光谱成像中化学位移伪影的减少