Improving model-data mismatch for photon-counting detector model using global and local model parameters
DOI:10.1002/mp.16883.png)
摘要
En 中文
BackgroundAn energy-discriminating capability of a photon counting detector (PCD) can provide many clinical advantages, but several factors, such as charge sharing (CS) and pulse pileup (PP), degrade the capability by distorting the measured x-ray spectrum. To fully exploit the merits of PCDs, it is important to characterize the output of PCDs. Previously proposed PCD output models showed decent agreement with physical PCDs; however, there were still scopes to be improved: a global model-data mismatch and pixel-to-pixel variations.PurposesIn this study, we improve a PCD model by using count-rate-dependent model parameters to address the issues and evaluate agreement against physical PCDs.MethodsThe proposed model is based on the cascaded model, and we made model parameters condition-dependent and pixel-specific to deal with the global model-data mismatch and the pixel-to-pixel variation. The parameters are determined by a procedure for model parameter estimation with data acquired from different thicknesses of water or aluminum at different x-ray tube currents. To analyze the effects of having proposed model parameters, we compared three setups of our model: a model with default parameters, a model with global parameters, and a model with global-and-local parameters. For experimental validation, we used CdZnTe-based PCDs, and assessed the performance of the models by calculating the mean absolute percentage errors (MAPEs) between the model outputs and the actual measurements from low count-rates to high count-rates, which have deadtime losses of up to 24%.ResultsThe outputs of the proposed model visually matched well with the PCD measurements for all test data. For the test data, the MAPEs averaged over all the bins were 49.2-51.1% for a model with default parameters, 8.0-9.8% for a model with the global parameters, and 1.2-2.7% for a model with the global-and-local parameters.ConclusionThe proposed model can estimate the outputs of physical PCDs with high accuracy from low to high count-rates. We expect that our model will be actively utilized in applications where the pixel-by-pixel accuracy of a PCD model is important.
Keyword:
charge sharing
computed tomography
photon counting detectors
pulse pileup
期刊
IF:
3.2
论文数:
3.7W
被引数:
3.2W
机构
引用论文
An analytical model of the effects of pulse pileup on the energy spectrum recorded by energy resolved photon counting x-ray detectors脉冲堆积对能量分辨光子计数x射线探测器记录的能谱的影响的分析模型
MEDICAL PHYSICS
IF3.2
A cascaded model of spectral distortions due to spectral response effects and pulse pileup effects in a photon-counting x-ray detector for CT用于CT的光子计数x射线探测器中由于光谱响应效应和脉冲堆积效应引起的光谱失真的级联模型
MEDICAL PHYSICS
IF3.2
Vision 20/20: Single photon counting x-ray detectors in medical imaging视觉20/20: 医学成像中的单光子计数x射线探测器
MEDICAL PHYSICS
IF3.2
Estimator for photon counting energy selective x-ray imaging with multibin pulse height analysis
MEDICAL PHYSICS
IF3.2
Modeling the performance of a photon counting x-ray detector for CT: Energy response and pulse pileup effects用于CT的光子计数x射线探测器的性能建模: 能量响应和脉冲堆积效应
MEDICAL PHYSICS
IF3.2