arrow
返回

Increased ion throughput using tristate ion-gate multiplexing

delete2019-01-01
delete32
PRE
AI
P
Pearl Kwantwi-Barima
T
Tobias Reinecke
B
Brian H. Clowers *
DOI:10.1039/c9an01585jdelete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
For time dispersive ion mobility experiments detail control over the mechanism of ion beam modulation is necessary to establish optimum performance as this parameter greatly influences the temporal width of the ion beam arriving at the detector. When sampling continuous ion sources the temporal sampling or the incoming ion beam is often achieved by the electronic modulation of a grid or electric field. Not surprisingly, the rate at which a given ion population traverses this gating region is directly proportional to an ion's population and the applied electric field. This scenario establishes conditions where discrimination of the incoming ion beam may occur when the ion gate modulation rate is minimized. Recent developments in the mechanical construction of ion gates and their subsequent operation suggest that the mobility discrimination during ion gating may be minimized, however, it is remains unclear how this behavior will translate to ion beam multiplexing approaches. In this present work, we compare the performance levels of the tri-state ion shutter (3S-IS) to the two-state ion shutter (2S-IS) using a series of Fourier transform ion mobility mass spectrometry (FT-IMMS) experiments. The performance of the two different shutter operating principles were evaluated using ion multiplexing using tetraalkylammonium salts (TXA ions; T5-T8, T10, T12) bradykinin, and a set of reversed sequence isomeric pentapeptides using a variety of different ion gate frequency sweeps. Noticeable increases in ion throughput were observed for the 3S-IS with 95% and 45% increases in ion counts for the T5 and T12 ions respectively compared to the 2S-IS. Similarly, a 27% and 55% increase in ion counts was observed for the [M + 2H](2+) and [M + H](+) ions of bradykinin, respectively. In addition, a 10% increase in resolving power was also observed for the 3S-IS compared to the 2S-IS. Overall, utilization of the 3S-IS effectively minimizes both discrimination of slower ions and the impact of gate depletion effect common to traditional ion gating techniques.
Keyword:
MOBILITY-MASS-SPECTROMETRY
COLLISION CROSS-SECTIONS
MIXTURES
PROTEINS
PEPTIDE
IMS
AI总结

AI总结

对已上传原文的论文进行重点信息的提取,主要内容包括:简要概述、研究摘要、背景介绍、关键亮点、图文解析、展望与总结。

期刊

A
Analyst
IF:
3.3
论文数:
1.6W
被引数:
3.3W

机构

W
washington state university
学者数:
1.8W
论文数: 1.6W
被引数: 114
引用论文

引用论文

Shape Changes Induced by N-Terminal Platination of Ubiquitin by Cisplatin
err2011-11-22
err54
PREAI
errWilliams, Jonathan P.; Phillips, Hazel I. A.; Campuzano, Iain; Sadler, Peter J.
err分享
err收藏
err分享
err收藏
IMS-IMS and IMS-IMS-IMS/MS for separating peptide and protein fragment ions
err2006-03-08
err218
PREAI
errMerenbloom, SI; Koeniger, SL; Valentine, SJ; Plasencia, MD; Clemmer, DE
err分享
err收藏
Ion mobility mass spectrometry for peptide analysis
errMETHODS
IF4.3
err2011-08-01
err81
PREAI
errHarvey, Sophie R.; MacPhee, Cait E.; Barran, Perdita E.
err分享
err收藏
Tracking Health Care Costs
err2001-01-01
err0
errOAAI
errBradley C. Strunk; Paul B. Ginsburg; Jon R. Gabel
err分享
err收藏
Separation of Isotopologues in Ultra-High-Resolution Ion Mobility Spectrometry
err2017-01-12
err62
errOAAI
errKirk, Ansgar T.; Raddatz, Christian-Robert; Zimmermann, Stefan
err分享
err收藏
err分享
err收藏
学者 查看更多内容