Inter-scanner Aβ-PET harmonization using barrel phantom spatial resolution matching

delete2024-03-11
delete2
delete
OA
AI
G
Gihan P. Ruwanpathirana
R
Robert Williams
C
Colin L. Masters
C
Christopher C. Rowe
L
Leigh A. Johnston
C
Catherine E. Davey *
DOI:10.1002/dad2.12561delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
INTRODUCTIONThe standardized uptake value ratio (SUVR) is used to measure amyloid beta-positron emission tomography (A beta-PET) uptake in the brainDifferences in PET scanner technologies and image reconstruction techniques can lead to variability in PET images across scanners. This poses a challenge for A beta-PET studies conducted in multiple centers. The aim of harmonization is to achieve consistent A beta-PET measurements across different scanners. In this study, we propose an A beta-PET harmonization method of matching spatial resolution, as measured via a barrel phantom, across PET scanners. Our approach was validated using paired subject data, for which patients were imaged on multiple scanners.METHODSIn this study, three different PET scanners were evaluated: the Siemens Biograph Vision 600, Siemens Biograph molecular computed tomography (mCT), and Philips Gemini TF64. A total of five, eight, and five subjects were each scanned twice with [18F]-NAV4694 across Vision-mCT, mCT-Philips, and Vision-Philips scanner pairs. The Vision and mCT scans were reconstructed using various iterations, subsets, and post-reconstruction Gaussian smoothing, whereas only one reconstruction configuration was used for the Philips scans. The full-width at half-maximum (FWHM) of each reconstruction configuration was calculated using [18F]-filled barrel phantom scans with the Society of Nuclear Medicine and Molecular Imaging (SNMMI) phantom analysis toolkit. Regional SUVRs were calculated from 72 brain regions using the automated anatomical labelling atlas 3 (AAL3) atlas for each subject and reconstruction configuration. Statistical similarity between SUVRs was assessed using paired (within subject) t-tests for each pair of reconstructions across scanners; the higher the p-value, the greater the similarity between the SUVRs.RESULTSVision-mCT harmonization: Vision reconstruction with FWHM = 4.10 mm and mCT reconstruction with FWHM = 4.30 mm gave the maximal statistical similarity (maximum p-value) between regional SUVRs. Philips-mCT harmonization: The FWHM of the Philips reconstruction was 8.2 mm and the mCT reconstruction with the FWHM of 9.35 mm, which gave the maximal statistical similarity between regional SUVRs. Philips-Vision harmonization: The Vision reconstruction with an FWHM of 9.1 mm gave the maximal statistical similarity between regional SUVRs when compared with the Philips reconstruction of 8.2 mm and were selected as the harmonized for each scanner pair.CONCLUSIONBased on data obtained from three sets of participants, each scanned on a pair of PET scanners, it has been verified that using reconstruction configurations that produce matched-barrel, phantom spatial resolutions results in maximally harmonized A beta-PET quantitation between scanner pairs. This finding is encouraging for the use of PET scanners in multi-center trials or updates during longitudinal studies.Highlights Question: Does the process of matching the barrel phantom-derived spatial resolution between scanners harmonize amyloid beta-standardized uptake value ratio (A beta-SUVR) quantitation? Pertinent findings: It has been validated that reconstruction pairs with matched barrel phantom-derived spatial resolution maximize the similarity between subjects paired A beta-PET (positron emission tomography) SUVR values recorded on two scanners. Implications for patient care: Harmonization between scanners in multi-center trials and PET camera updates in longitudinal studies can be achieved using a simple and efficient phantom measurement procedure, beneficial for the validity of A beta-PET quantitation measurements.
Keyword:
amyloid beta
PET scanner harmonization
Philips TF64
SIEMENS mCT
SIEMENS Vision

期刊

A
Alzheimer's and Dementia: Diagnosis, Assessment and Disease Monitoring
IF:
4.4
论文数:
807
被引数:
3.0K

机构

U
university of melbourne
学者数:
5.7W
论文数: 5.4W
被引数: 69
引用论文

引用论文

FDG PET/CT: EANM procedure guidelines for tumour imaging: version 2.0FDG PET/CT: EANM肿瘤成像程序指南: 2.0版
err2014-12-02
err2.3K
errOAAI
errBoellaard, Ronald; Delgado-Bolton, Roberto; Oyen, Wim J. G.; Giammarile, Francesco; Tatsch, Klaus; Eschner, Wolfgang; Verzijlbergen, Fred J.; Barrington, Sally F.; Pike, Lucy C.; Weber, Wolfgang A.; Stroobants, Sigrid; Delbeke, Dominique; Donohoe, Kevin J.; Holbrook, Scott; Graham, Michael M.; Testanera, Giorgio; Hoekstra, Otto S.; Zijlstra, Josee; Visser, Eric; Hoekstra, Corneline J.; Pruim, Jan; Willemsen, Antoon; Arends, Bertjan; Kotzerke, Joerg; Bockisch, Andreas; Beyer, Thomas; Chiti, Arturo; Krause, Bernd J.
err分享
err收藏
Phantom criteria for qualification of brain FDG and amyloid PET across different cameras
err2016-10-06
err37
errOAAI
errIkari, Yasuhiko; Akamatsu, Go; Nishio, Tomoyuki; Ishii, Kenji; Ito, Kengo; Iwatsubo, Takeshi; Senda, Michio
err分享
err收藏
In Vivo Imaging of Amyloid Deposition in Alzheimer Disease Using the Radioligand 18F-AV-45 (Flobetapir F 18)
err2010-05-25
err591
errOAAI
errWong, Dean F.; Rosenberg, Paul B.; Zhou, Yun; Kumar, Anil; Raymont, Vanessa; Ravert, Hayden T.; Dannals, Robert F.; Nandi, Ayon; Brasic, James R.; Ye, Weiguo; Hilton, John; Lyketsos, Constantine; Kung, Hank F.; Joshi, Abhinay D.; Skovronsky, Daniel M.; Pontecorvo, Michael J.
err分享
err收藏
18F-Flutemetamol Amyloid Imaging in Alzheimer Disease and Mild Cognitive Impairment A Phase 2 Trial
err2010-08-30
err562
PREAI
errVandenberghe, Rik; Van Laere, Koen; Ivanoiu, Adrian; Salmon, Eric; Bastin, Christine; Triau, Eric; Hasselbalch, Steen; Law, Ian; Andersen, Allan; Korner, Alex; Minthon, Lennart; Garraux, Gaetan; Nelissen, Natalie; Bormans, Guy; Buckley, Chris; Owenius, Rikard; Thurfjell, Lennart; Farrar, Gill; Brooks, David J.
err分享
err收藏
Amyloid Imaging with 18F-Florbetaben in Alzheimer Disease and Other Dementias
err2011-07-15
err296
errOAAI
errVillemagne, Victor L.; Ong, Kevin; Mulligan, Rachel S.; Holl, Gerhard; Pejoska, Svetlana; Jones, Gareth; O'Keefe, Graeme; Ackerman, Uwe; Tochon-Danguy, Henri; Chan, J. Gordon; Reininger, Cornelia B.; Fels, Lueder; Putz, Barbara; Rohde, Beate; Masters, Colin L.; Rowe, Christopher C.
err分享
err收藏
Clinical evaluation of PET image reconstruction using a spatial resolution model使用空间分辨率模型对PET图像重建的临床评估
err2013-05-01
err47
PREAI
errAndersen, Flemming Littrup; Klausen, Thomas Levin; Loft, Annika; Beyer, Thomas; Holm, Soren
err分享
err收藏
The Alzheimer's Disease Neuroimaging Initiative positron emission tomography core
err2010-05-01
err436
errOAAI
errJagust, William J.; Bandy, Dan; Chen, Kewei; Foster, Norman L.; Landau, Susan M.; Mathis, Chester A.; Price, Julie C.; Reiman, Eric M.; Skovronsky, Daniel; Koeppe, Robert A.
err分享
err收藏
Harmonisation of PET/CT contrast recovery performance for brain studies
err2021-01-31
err27
errOAAI
errVerwer, E. E.; Golla, S. S. V.; Kaalep, A.; Lubberink, M.; van Velden, F. H. P.; Bettinardi, V.; Yaqub, M.; Sera, T.; Rijnsdorp, S.; Lammertsma, A. A.; Boellaard, R.
err分享
err收藏
学者 查看更多内容