arrow
返回

Ion Mobility Separations Using Cocentric Architecture

delete2024-06-11
delete1
PRE
AI
P
Pearl Kwantwi-Barima
A
Adam Hollerbach
I
Isaac Attah
R
Randolph V. Norheim
Y
Yehia Ibrahim *
DOI:10.1021/jasms.4c00163delete
delete原文链接
delete原文求助
delete分享
delete收藏
摘要

摘要

En 中文
Ion mobility separations, especially using drift tube ion mobility spectrometers, are usually performed in linear channels, which can have a large footprint when extended to achieve higher resolving powers. In this work, we explored the performance of an ion mobility device with a curved architecture, which can have a more compact form. The cocentric ion mobility spectrometer (CoCIMS) manipulates ions between two cocentric surfaces containing a serpentine track. The mobility separation inside the CoCIMS is achieved using traveling waveforms (TWs). We initially evaluated the device using ion trajectory simulations using SIMION, which indicated that when ions traveled circularly inside the CoCIMS they resulted in similar resolving powers and transmitted m/z range as traveling in a straight path. We then performed experimental validation of the CoCIMS in conjunction with a TOF MS. The CoCIMS was made of two flexible printed circuit board materials folded into cocentric cylinders separated by a gap of 2.8 mm. The device was about 50 mm diameter x152 mm long and provided 1.846 m of serpentine path length. Three sets of mixtures (Agilent tune mixture, tetraalkylammonium salts, and an eight-peptide mixture) and four traveling waveform profiles (square, sine, triangle, and sawtooth) were used. The sawtooth TW profile produced a slightly higher resolving power for the Agilent tuning mixture and tetraalkylammonium ions. The average resolving power for Agilent tune mixture ions ranged from 37 (using sawtooth TW) to 27 (using square TW). The average resolving powers ranged from 45 (sawtooth TW) to 31 (square TW) for tetraalkylammonium ions. The resolving power of the peptide mixture ions was similar among the four TW profiles and ranged from 51 to 56. The average percent error in (CCS)-C-TW for the peptide mixture ions was about 0.4%. The new device showed promising results, but improvements are needed to further increase the resolving power.
Keyword:
MASS-SPECTROMETRY
TRAVELING-WAVES
FUNDAMENTALS
EXPLOSIVES
PATH

期刊

Journal of the American Society for Mass Spectrometry 封面图
Journal of the American Society for Mass Spectrometry
IF:
2.7
论文数:
7.2K
被引数:
1.1W

机构

U
united states department of energy (doe)
学者数:
11.3W
论文数: 9.6W
被引数: 246
引用论文

引用论文

An Interlaboratory Evaluation of Drift Tube Ion Mobility-Mass Spectrometry Collision Cross Section Measurements
err2017-08-16
err450
errOAAI
errStow, Sarah M.; Causon, Tim J.; Zheng, Xueyun; Kurulugama, Ruwan T.; Mairinger, Teresa; May, Jody C.; Rennie, Emma E.; Baker, Erin S.; Smith, Richard D.; McLean, John A.; Hann, Stephan; Fjeldsted, John C.
err分享
err收藏
Serpentine Ultralong Path with Extended Routing (SUPER) High Resolution Traveling Wave Ion Mobility-MS using Structures for Lossless Ion Manipulations
err2017-04-05
err219
errOAAI
errDeng, Liulin; Webb, Ian K.; Garimella, Sandilya V. B.; Hamid, Ahmed M.; Zheng, Xueyun; Norheim, Randolph V.; Prost, Spencer A.; Anderson, Gordon A.; Sandoval, Jeremy A.; Baker, Erin S.; Ibrahim, Yehia M.; Smith, Richard D.
err分享
err收藏
Classification of actions or Inheritance also for methods
err2000-08-25
err0
PREAI
errBent Bruun Kristensen; Ole Lehrmann Madsen; Birger Møller-Pedersen; Kristen Nygaard
err分享
err收藏
An IMS-IMS analogue of MS-MS
err2006-05-11
err296
PREAI
errKoeniger, Stormy L.; Merenbloom, Samuel I.; Valentine, Stephen J.; Jarrold, Martin F.; Udseth, Harold R.; Smith, Richard D.; Clemmer, David E.
err分享
err收藏
Enhancing bottom-up and top-down proteomic measurements with ion mobility separations
err2015-07-03
err61
errOAAI
errBaker, Erin Shammel; Burnum-Johnson, Kristin E.; Ibrahim, Yehia M.; Orton, Daniel J.; Monroe, Matthew E.; Kelly, Ryan T.; Moore, Ronald J.; Zhang, Xing; Theberge, Roger; Costello, Catherine E.; Smith, Richard D.
err分享
err收藏
Biomolecule Analysis by Ion Mobility Spectrometry
err2008-07-01
err517
errOAAI
errBohrer, Brian C.; Mererbloom, Samuel I.; Koeniger, Stormy L.; Hilderbrand, Amy E.; Clemmer, David E.
err分享
err收藏
Tuning Mobility Separation Factors of Chemical Warfare Agent Degradation Products via Selective Ion-Neutral Clustering
err2017-11-03
err32
PREAI
errKwantwi-Barima, Pearl; Ouyang, Hui; Hogan, Christopher J., Jr.; Clowers, Brian H.
err分享
err收藏
Fundamentals of Traveling Wave Ion Mobility Spectrometry
err2008-11-06
err550
errOAAI
errShvartsburg, Alexandre A.; Smith, Richard D.
err分享
err收藏
学者 查看更多内容